Roof heating cable


In the winter and spring, we all face the problem of ice on the roofs of our houses.
Due to the fact that the temperature at this time of year very often passes through zero (in both directions), such changes lead to the formation of pieces of ice and icicles.

In addition to the fact that roof elements suffer and deteriorate as a result, the entire perimeter of the house turns into a potential minefield.

You don't know where and when someone might fly from above. And it’s good if this block falls on a parked car, and not on your head.

Not only private owners, but also city services face the same problem. For example, in Moscow alone, the total length of the entire roof is greater than the length of the equator!

The main places where ice accumulates are:

  • valley
  • drainpipes
  • gutter
  • drip

This problem can and should be solved preventively in the summer. You can't really climb on the roof in winter.

Anti-icing systems for roofs and gutters, made on the basis of a heating cable, help with this.

What does this all look like in general? The cable is spread along the drain and the edges of the roof, the “cold” ends from it are fed into junction boxes on the walls. Temperature, humidity and precipitation sensors are placed along the perimeter and on the roof.

The cables from them are also fed into a common box under the canopy. And from there all the wiring goes down to the control panel with automation.

Although the pleasure is not cheap (from 100,000 rubles for a small private house), it is effective.

Heat the roof or gutter?

How to select materials and install everything correctly, without overpaying for unnecessary things? Here everything will depend on the thermal insulation of your roof.

If everything is fine with it, warm air from inside the house simply will not be able to get out, the roof will not heat up, which means there will simply be nothing for icicles to form from.

In this case, ice will only appear at outside temperatures not lower than -5C.

Mistake #1

In this situation, there is no need to heat the roof itself, but it is enough to get by with heating only the drainage system.

Thermal insulation and energy efficiency, as they say, rule.

But if the roof’s thermal insulation is of poor quality, the snow begins to melt even at relatively low air temperatures (-10C).

In this situation, water will flow towards the bottom edge and gutters.

It will freeze there, turning into pieces of ice. Here you will already need to lay a cable for complex heating:

  • the roof itself
  • gutters
  • gutters

Cable selection

Mistake #2

Please note that a completely different heating cable is used here, different from what is laid in heated floors inside the house.

Its shell is made of a special heat-resistant, light-stabilized PVC plastic compound. This material is not afraid of exposure to ultraviolet radiation and harsh climatic conditions.

There are two types of such cable:

  • self-regulating
  • resistive

For an ordinary home, the second option is quite suitable. It has constant power and, in addition to being inexpensive, is more reliable than a self-regulating one.

How much cable do you need - footage and power?

How to calculate the required cable footage? To do this, multiply the total length of the gutter and drain pipe by two (when installing two heating lines).

Then calculate the height of the cable on the roof and add the distance from the end of the roof to the bottom of the gutter.

Taking into account the recommended laying step of 10-15 cm, you will get the length of the heating section and the entire anti-icing system.

Mistake #3

Do not forget that excess cable is the same disadvantage as lack of length.

What power cable should I choose? With a gutter width of up to 15 cm, it will be enough to lay one thread with a power of 30-40 W/m.

Mistake #4

If you use cable less than 30W/m you will face serious problems. The system simply will not cope with its tasks at certain temperatures and heavy precipitation.

If no other power is found, use more threads.

For gutters wider than 15cm, you will need to lay two strands of cable. The power is the same - 30-40W/m.

Let's look at the entire cycle of installing a roof heating system and connecting automation for a house with a roof that has poor thermal insulation. That is, when it is necessary to de-ice not only the gutters, but also the roof itself.

Heating of roofs, gutters, industrial facilitiesExpand

Cost of main works

Installation of heating cable at height From 300 rub./linear meter
Installation of power cable From 170 rub./linear meter
Insulating the heating cable and connecting to the power cable 600 rub./pcs.

Installing a thermostat

Installation of weather station temperature sensor From 160 rub./linear meter
Installation of a thermostat 520 RUR/pcs.

Installation of a roof anti-icing system - materials

To install the anti-ice system you will need the following materials:

  • three-wire power cable 220V – VVG

  • panel for control equipment

  • automation (full equipment will be given below in the diagrams)

  • cable KVVG

This is the control cable that will connect the sensors.

  • protective junction boxes

They must have a degree of protection IP55.

  • mounting tape for fastening the heating cable

  • galvanized rope or chain

  • mounting clips

  • resistive heating cable itself

Where does installation begin? First of all, measure the cable on the ground along the mounting tape. Choose the distance between the tapes from 30 to 50cm.

The descent into the drain is immediately measured and the cable is installed.

Cost of laying heating cable

Specialists are ready to install and configure the anti-icing system, connect the heating cable to the electrical panel and install everything necessary for manual or automatic adjustment of the heating level. To make a final decision, we recommend that you contact our experts by phone and receive detailed advice on all related issues. We offer the best price for installing a heating cable on a roof in the region, as well as an official guarantee for the work performed by our craftsmen!

The cost of installing a heating cable on the roof may increase due to the following factors:

  • Cable laying is carried out at sub-zero temperatures;
  • there is no free access to the work site;
  • it is necessary to use special equipment or industrial climbers;
  • surfaces are not prepared, for example, they are dirty or icy.

The cost of installation work is calculated on an individual basis after our technician visits your site and takes all necessary measurements. The type and complexity of the roof, the features of the installed drainage system, the thickness of the installed heating cable, the need to install temperature sensors and automation to control subsequent heating are taken into account.

Name of serviceprice of work per 1 linear meter (rub.)
Installation of cable on the roof surface300 – 350
Cable laying in open areas120 – 200
Installation of cables on drains outside115 – 190
Laying cables on gutters inside165 – 210
Tightening the power cable into the corrugation45
Drilling through holes in load-bearing walls1100
Assembly of electrical panels and automatic temperature control systems500 – 5000
Connection of electrical panels and commissioning2000
Installation of temperature sensors on the roof450
Installation of temperature sensors in the gutter450

How to secure cable to roof and gutter

After this, screw the fastening clips or tape onto the roof.

To prevent leaks, do not forget to treat the entry points of the screws with sealant.

The step between the top and bottom rows of clips is 60cm.

Mistake #5

To install the heating cable on the roof, use only specialized fasteners.

Forget about the cable ties that are often used to run cables along the walls of the house.

For certain types of roofing, special petals with latches are produced. You don't even have to make holes with them.

There is also a fastening method using self-adhesive sealing tape on an aluminum base.

According to the manufacturer, the tape has a high level of adhesion, is heat-resistant and durable. But still, the majority prefer through cable fastening, considering it more pragmatic and reliable.

Before installing the heating cable, be sure to check its resistance and integrity of the wires with a multimeter.

Resistance data must be indicated in the product passport.

If everything is in order, lay the cable in waves according to the fixed clips on the roof slope.

After which, the cold end is inserted into the installation box under the ridge.

Sections for drainage are also called. Both between the working conductors and with the protective conductor.

Between the grounding protective conductor and the working conductors, the insulation should reach several megohms.

This check is no longer carried out with a multimeter, but with a megger.

Be sure to write down all the data in your passport so that you have something to compare with later. Suddenly, in a few years you will need to find the reason for the system's inoperability.

After all checks, the gutter is thoroughly cleaned of dirt and debris.

A mounting tape is secured inside it. Most often this is done on rivets.


But there is also a rivetless fastening.

It is best to use a combined option. Every 1.0-1.5 m you rivet the tape, and in the middle of these sections you place plastic spacers that simply push the cable apart.

The horizontal section of the cable is laid in the gutter, and the vertical section is lowered down the drain using a cable.

Please note that if you have pets at home, they love to chew on such a cable, provocatively peeking out of the pipe.

Mistake #6

In this situation, you cannot release it outside, and it is better to hide the noose inside.

The cable of the vertical section of the cable is suspended on a hook.

This cable is required for pipe heights over 4 m. By the way, when laying cables in the valley, a support cable is also often used.

It absorbs all mechanical load, protecting the shell from damage.

Instead of a cable, you can use a chain in the drain. It must be galvanized so that it does not rust from constant contact with water.

The cable is simply put on individual links through special spacers.

The last link from above is suspended on a spacer rod or pin.

The pin itself should not just lie across the hole in the drain, it is advisable to secure it.

For example, for the same mounting tape.

Mistake #7

Do not skimp and do not lower the cable into the pipe without such a chain or cable.

They perform a protective function. If the system fails, ice very quickly sticks to the cable in the drain, increasing its weight several times.

And so that it does not break from such a load, an additional load-bearing element is required.

After installation, all cold ends of the cables are inserted into the installation box.

The whole process is repeated on all roof slopes.

If you have an extension without gutters (garage), the cable is also placed on it, but in such a way that its loops hang down a few centimeters (5-8cm).

This is the so-called “drip loop” scheme.

Heating of water supply and sewerage pipesExpand

Cost of main works

Installation of a heating cable in/on a pipe From 180 rub./linear meter
Installation of insulation on a pipe From 95 RUR/linear meter
Installation of power cable (corrugated) From 170 rub./linear meter
Insulating the heating cable and connecting to the power cable 600 rub./pcs.

Installing a thermostat

Grooving under a corrugated pipe (depending on the type of surface of the wall or floor) From 100 rub./linear meter
Installation of a thermostat 520 RUR/pcs.

May be needed

Cable entry device into pipe From 580 RUR/pcs.
Walking the Wall (Easy) From RUB 150/hole

Installation and connection of automatic roof heating systems

Let's move on to connecting the automation. To control the entire roof and gutter anti-icing system, you will need the following components:

  • modular input circuit breaker + RCD with leakage current of 30 mA

Or they can be replaced with one diffautomatic circuit breaker with the same current.

  • modular starter with normally open contacts

  • 3 position switch

To switch the system to manual and automatic modes.

  • thermostat or weather station

The brains of the entire system.

  • automatic switches for heating sections
  • humidity, temperature, precipitation sensors

Types of electrical cable

When choosing an electrical cable for a heating system, you should consider

:

  • specifications;
  • the ability to change the installation length (a cable with a fixed length of segments is more difficult to install);
  • specifics of use (manufacturer's recommendations regarding installation location).

Domestic and foreign manufacturers offer various types of electrical cables

:

  • resistive;
  • armored;
  • zonal;
  • self-regulating.

Resistive heating cable for roofing is characterized by a fixed length of sections, which can be 10 - 200 meters. The released power is from 5 to 30 W/m. The advantages of the product include its affordable price. The downside is the same heat transfer along the entire length, while different sections of the roof require different amounts of heat. As a result, in some areas the system will run idle, while in others its power will not be enough for the necessary heating of the structure.

Be sure to read: Heating the roof and gutters using cable

Armored electrical cable is a fairly new invention. Unlike resistive, it has a heating temperature of up to 150 °C and has increased mechanical strength. It is used for installation on existing roofs, since this type of heating cable is laid on a concrete base. During the process, you can adjust the length of the segment within 1-2 meters.

Zone cable is primarily intended for installation in drainpipes and gutters. Like resistive, zonal is characterized by a fixed heat transfer power (up to 200 W/m). In this case, the installation of heating cables on the roof can be done with free adjustment in length during the installation process.

Self-regulating is characterized by the ability to adapt to environmental conditions. Heat transfer varies between 6-100 W/m and completely depends on the amount of ice in the installation area. To install a roof heating system, a self-regulating thread can be laid in pieces of any length - only the maximum length is limited, which ranges from 6 to 150 meters, depending on the brand.

The self-regulating cable pays for its high cost during the operation of the system, which has less need for distribution lines and provides significant energy savings.

Anti-icing system for roofing

The roof heating system includes a number of devices and components, including

:

  • heating cable with fasteners for the appropriate type of roof;
  • roof funnel with electric heating;
  • snow retention elements that prevent cable damage;
  • communication lines (power and information wires, etc.);
  • sensors, thermostats, automatic system controls.

The use of residual current equipment is mandatory! If the wire insulation is broken, such a device instantly de-energizes the heating lines.

A simple roof heating connection diagram

The simplest scheme consists of a single thermostat for one zone.

It is used for heating small areas.

Roughly speaking, we connected one temperature sensor and unscrewed the knob of the regulator (RT 330 or another) to the desired temperature, for example, zero degrees Celsius.

It turns out that when this temperature occurs, the anti-icing system will start on its own and melt the ice.

The scheme is simple, but has its drawbacks. This system will not understand whether it is snowing outside the window or not.

This means that very often it will be useless to heat your roof, burning extra kilowatts to nothing. This method, although cheap, is not very economical.

Therefore, let's look at a more rational option, using a full-fledged programmable weather station and a combination of all sensors.