Elimination of errors that occur during operation of Kiturami gas boilers

We're sure you're not a fan of unexpected expenses. And you probably don’t want to replace a completely new boiler because of a problem that was not resolved in time. Meanwhile, problems appear even in devices that work for the first day. In the article we wrote about errors in Kiturami gas boilers and their codes. Read it. Even if you do not have heating equipment of this brand, it is better to learn more about it - you will understand whether it is worth buying it in the future.

You will learn to recognize errors in Kiturami boilers. Find out what causes them, in addition to the main reasons. For convenience, we have presented their codes in ascending order. Immediately after them, other failures and problems that do not have codes were indicated. Read the article and you will know what to do if a malfunction occurs.

Boiler errors are determined through codes. They differ among manufacturers. On Kiturami devices, combinations of numbers from 01 to 98 pop up. The decodings are the same for all boilers of this brand that run on gas. They can differ only because of the names of individual modules.

Gas boilers Kiturami

Kiturami has been making boilers since 1962 and produces up to 9,000 units daily. Kiturami produces devices that run on gas, diesel fuel, and solid pellets. Gas boilers are manufactured for fuel in accordance with GOST 5542-2014.

Most products from the South Korean manufacturer have a dual-circuit structure, a closed combustion chamber and are fully automated. The efficiency of the devices reaches 94%.


The Kiturami company uses low-carbon technologies, equips its boilers with a large number of fuses and sensors, and makes compact and advanced internal structures

Popular models of Kiturami gas boilers:

  • World Plus;
  • Eco Condensing;
  • TGB;
  • KSG;
  • World Alpha;
  • Twin Alpha;
  • World 3000;
  • World 5000.

The power of Kiturami boilers reaches 465 kW, and for wall-mounted models it ranges from 13-35 kW. Their turbocyclone burners operate at low pressure - about 30 mm of air column. Each type of fuel has its own burner models that can operate on the same boiler.

Kiturami appliances have protection against freezing and blowing out the chimney. Heat exchangers in World Plus devices maintain their quality even after long-term use of “hard” water.

Kiturami gas boilers last up to 15 years or more, much depends on the conditions of use. Devices display errors with simple numbering - from 01 or from Er 01. Read about them to quickly fix problems and keep the device in working order.

Error codes 01 – 08

Errors 01 to 03 indicate that the control system does not see the flame or has blocked ignition - before or after starting.


Errors 01, 02 and 03 often appear due to a closed valve - open it and restart the device, at the same time check the air supply to the boiler

Code 01 - no flame. Perform the actions from the list, and if nothing changes, move on to the following points:

  1. Open the gas supply valve to maximum.
  2. Bleed air from the heating system.
  3. Inspect the grounding. The wire may have lost its integrity, or it may have been routed incorrectly. Re-ground to a depth of 30 cm or more.
  4. Compare the gas pressure in the boiler with the indicator in the instructions. If there is a discrepancy, call the gas workers.
  5. Check the integrity of the ignition wire and its power source.
  6. Remove soot and dirt from the boiler burner.
  7. Also clean the ignition and control electrodes. Soot and deposits collect on them. Reposition the electrodes according to the instructions if the inclination has changed. Check if they work at all.
  8. Check that the gas valve and photocell of the flame detection system are working properly. Replace elements with new ones if necessary.
  9. Check the circuit board, connections and wires that go to it. Replace if necessary.

Code 02 - false flame or its defect. Check and, if necessary, replace the photocell of the flame control system. Replace the board if it is broken beyond repair.

Check it for oxidation, open circuit, short circuit. The burner nozzles could cause the electrodes to become dirty. Clean them and put them in the correct position.

Code 03 - the flame appears and disappears for a short time. Check the flame sensor and replace the faulty device. Check the pressure on the pressure gauge. Contact your gas service if the reading is outside the normal range.


The structure of the Kiturami boiler along with the flame sensor (photocell) of the flame control system, pressure gauge in the lower left corner and gas valve

The problem may be ventilation. Open windows and doors, inspect the built-in ventilation ducts of the room. The error remains - check the external condition of the boiler fan and determine the resistance with a multimeter. The device could break. Also look into the chimney and remove any dirt.

Code 04 - the temperature sensor of the heating element is not working correctly. Inspect the wires that go to the sensor. Connect the broken wires and clean the oxidized contacts. Check the sensor for an open or short circuit. Inspect the control board. If something happens, contact a service that professionally repairs Kiturami brand gas boilers - they are repaired in many service centers in Russian cities. Replace these components if necessary.

Code 05 - overheating sensor failure. Ring the seismic sensor if your boiler has one. Replace if necessary, but do not remove. Also inspect the overheat indicator itself. Determine the pressure in the system and add water if the reading drops. Take a look at the heat exchanger. If there is excess scale, clean the unit.

Code 06 - fan failure - fan speed cannot be determined.


Fan for Kiturami gas boiler: the device supplies air to the combustion chamber, removes flue gases and other combustion products

To fix the error you will need to take seven steps:

  1. Inspect the wires that go to the fan. Clean if oxidized. Restore broken contacts.
  2. Assess the condition of the fan blades. If there is noticeable wear and tear, purchase a new device.
  3. If the differential relay connections are stuck (including after they have come loose), replace the unit.
  4. Make sure that the mains voltage matches the required value. If not, install a transformer and an uninterruptible power supply.
  5. Clear the chimney of anything foreign.
  6. Inspect the fan rotating mechanism.
  7. Check the Hall sensor.

Replace any unusable parts.

Code 07 - problems with the chimney. The likely cause is the fan/blower speed being higher or lower than normal. Inspect the unit, remove foreign objects. At the same time, clean the chimney of dirt and condensation.

The error appears due to gusts of wind. If the problem occurs frequently, you will have to change the pipe pattern. You need to design taking into account the wind rose.


Many Kiturami boiler models come with CTR remote thermostats, which make it easier to regulate the room temperature and allow you to set the operating time

Code 08 - problem with the room temperature controller. The error appears when communication with the boiler control unit is disrupted. Code 08 will also appear if the length of the regulator wire exceeds 10 meters. Thermostat cables are sometimes exposed to telephone and high-voltage wires.

First of all, turn off the regulator and check the operation of the boiler. If everything is fine, first try to find a different location for the thermostat and turn it on again. Re-route the temperature sensor cable correctly if nothing has changed. Avoid placement in pipes under the floor.

Error codes 14 – 98

Let's start with similar errors - 14 and 34.

Code 14 - malfunction of the hot water outlet temperature meter. Look for a problem in the sensor itself and its wire.

Code 34 is an error of the same type regarding the hot water supply inlet temperature sensor.


After the DHW (hot water supply) sensor fails, the boiler will continue to heat the home, and regulating and maintaining the temperature of running water becomes impossible

Code 95 - indicates low pressure in the boiler/heating system, i.e. due to a lack of coolant (usually water).

Proceed like this:

  1. Check to see if there is water in the boiler and what pressure is in the heating circuit.
  2. Check and clean filters if necessary.
  3. Look for leaks in heating pipes and radiators. Then, eliminate leaks in the expansion tank and heat exchanger.
  4. Take a look at the expansion tank membrane. Replace if stretched or becomes too dirty.
  5. Add water to normal pressure.
  6. Inspect and repair the air valve on the pipe through which coolant enters the heating system.

Code 96 - the temperature indicator has activated. The temperature rose above the permissible 92...97 °C. The boiler will operate in emergency mode until the temperature drops. When the error disappears, restart your device.

Eliminate the cause of the temperature jump:

  1. Clean the heat exchanger from scale.
  2. Check and replace the circulation pump if necessary.
  3. Ring the thermostat. Buy a new one if repair is not possible.
  4. Do the same with the board.

Code 97 - possible gas leak. There could be a leak of natural gas near the burner. Stop the gas supply to the boiler and turn it off. Call the gas emergency service. Error 97 may also appear because air has accumulated in the system.


Technologies used in Kiturami boilers to ensure tightness: protection against water hammer and flue gas penetration in the upper part of the heat exchanger

Code 98 appears on liquid fuel appliances.
Indicates insufficient energy level in the fuel tank.

Probable errors and causes of occurrence

This article contains all possible malfunctions and options for eliminating them, as well as error codes for Kiturami boilers.
All information is read in the following order: code - name - possible malfunction. If you have any additional questions, please leave them in the comments to this article. The content of the article

  • Error code 01, 02, 03 - No ignition
  • Error code 04 - Temperature sensor signal error
  • Error code 05 - Error in the sensor signal that controls water overheating
  • Error code 07 - Fan error
  • Error code 08 - Communication between the boiler control unit and the room regulator CTR-5700 is broken
  • Error code 10 - Room remote control dirty
  • Error code 11 - Air pollution in the room (increased carbon monoxide)
  • Error code 14 - Problems with the DHW outlet temperature sensor
  • Error code 34 - Problems with the DHW inlet temperature sensor
  • Error code 95 - The coolant level is below the established norm
  • Error code 96 - The coolant water temperature exceeds the maximum permissible values
  • Error code 97 - Gas leak
  • Error code 98 - Fuel availability error
  • Error code 00 - Malfunction of the room remote control or the wire to it
  • Possible breakdowns
  • The LED on the control unit does not light up indicating the network
  • The light indicates low water level.
  • LED lights up indicating overheating
  • Security light is on
  • Pump running time is significantly longer than usual
  • The boiler takes longer than usual to reach the required temperature

Error code 01, 02, 03 - No ignition

  1. It is possible that gas is not entering the burner due to the shut-off valve being closed. It is necessary to open it, then restart the unit. The gas filter needs to be checked. If it is so contaminated that gas does not pass through, you must call a specialist from the nearest service center.
  2. The device lights up, but after that it stops due to an accident. It is necessary to make sure that the blinds and other openings that provide air access to it are not blocked.
  3. It is important to ensure that combustion products are successfully discharged into the chimney. Remove all detected obstacles. After this, you need to restart the unit. If the problem cannot be resolved on your own, it is recommended to contact your nearest service center.

Error code 04 - Temperature sensor signal error

The device does not receive a signal from the water temperature sensor, or the sensor is broken, or there is no connection. You need to turn off the unit and contact the nearest service center.

Error code 05 - Error in the sensor signal that controls water overheating

The Kiturami boiler does not receive signals from the sensor that controls water overheating. The sensor may be broken or the connection may be interrupted. You need to stop the device and contact the nearest service center.

Error code 07 - Fan error

There may be some foreign object in the fan, the rotation speed of the blades is either too high or too low. Strong wind entering the chimney affects the rotation speed of the fan. If this code appears, the smoke exhaust pipe must be adjusted and reinstalled. There may be condensation in one of the elbows. It should be removed. If you could not solve the problem on your own, you need to contact the nearest service center.

Error code 08 - Communication between the boiler control unit and the room regulator CTR-5700 is broken

The length of the wires through which this connection is carried out should be no more than 10 m. Also, the operation of this sensor is affected by devices or wires operating nearby. To verify the cause of the problem, you need to turn off the sensor and check how the device works. If the problem goes away, then you need to install the room regulator in another location. If the problem cannot be solved on your own, you must contact your nearest service center.

Error code 10 - Room remote control dirty

Press the “Restart” button on the room remote control - restart the boiler.

Error code 11 - Air pollution in the room (increased carbon monoxide)

It is necessary to ventilate the room.

Error code 14 - Problems with the DHW outlet temperature sensor

There is no contact with the sensor, or it is broken. You need to stop the boiler and contact the service center.

Error code 34 - Problems with the DHW inlet temperature sensor

There is no contact with the sensor, or it is broken. You need to turn off the unit and call a service technician.

Error code 95 - The coolant level is below the established norm

Make sure there is water in the boiler. Check the system for tightness. Check the pressure in the system. Make sure the automatic air valve is working. If the problems cannot be solved on your own, contact a specialist.

Error code 96 - The coolant water temperature exceeds the maximum permissible values

It is above 97 degrees. In this case, the circulation pump is forcibly turned on to ensure cooling of the water. You need to make sure that the coolant has cooled down and then restart the device. If the above malfunctions cannot be resolved, you need to contact your nearest service center.

Error code 97 - Gas leak

Urgently close the gas valve located in front of the unit. Call a gas service specialist.

Error code 98 - Fuel availability error

Check whether there is enough fuel and whether it is entering the boiler.

Error code 00 - Malfunction of the room remote control or the wire to it

Press the “Restart” button on the room remote control - restart the boiler.

If you are not 100% sure what exactly the problem is and that you can solve it, immediately contact the service center to diagnose and fix the problem.

Problems in the operation of Kiturami boilers

Not all problems have their own code, so we will consider them separately.

“Network” indicator does not light up - check the power in the outlet and the fuse on the ignition transformer. If there is no voltage in the electrical network, call an electrician; if there is, call the service department.

The indicator on the control unit lights up for insufficient water - there is no water in the device or the level is too low. Damage to the black wire of the boiler and the red cable of the sensor can also cause a problem.

The room temperature sensor works normally, but the radiators are cold - the circulation pump does not disperse the coolant through the pipes or does so too weakly. Inspect the locking parts on the heating pipes. Check the pump itself.

"Overheat" light comes on - the heating system is not working properly. Check her out.

If the problem persists, do the following:

  1. Adjust the shut-off valves on the heating pipes.
  2. The strainer may need cleaning. Examine it.
  3. Check the circulation pump, repair or replace if necessary.

The “Safety” diode lights up - gas enters the boiler burner in small quantities or does not enter at all. Inspect the valves and open them if necessary. The problem remains - call the gas workers.


Schematic representation of a room remote thermostat: it has 5 main modes, including presence, absence, shower, sleep, water heating control

The pump has been running for too long. The water temperature indicator on the control unit is constantly on - the heating system is not working properly or there are air pockets in it. Release the air.

The boiler takes longer to heat up - look for a problem with the gas pressure and the condition of the filters.

The burner vibrates when turned on - the size of the chimney is not enough for normal gas removal.

The efficiency of the device in terms of hot water supply and heating has decreased - bad water or dirt from the heating system enters the boiler. Chemical treatment of the circuits and heat exchanger will help.

Description of Kiturami malfunctions and repairs

The Kiturami diesel boiler belongs to the economy version and has a fairly long service life. But there are also situations when boilers fail prematurely. The reason for the need to repair Kiturami is their untimely maintenance or the use of low quality fuel.

You can carry out simple repairs of Turbo boilers yourself, but it is more rational to contact service organizations in case of malfunctions.

Rice. 3 Installed Kiturami boiler

Below are the main error codes that the Kiturami Turbo 17 diesel boiler most often experiences:

  • when the lights flash “01”, “02” or “03” on the display, it means there are problems in the flame detector and ignition does not occur. In this case, the Turbo boiler should be restarted according to the instructions;
  • error “04” indicates that the water temperature sensor is faulty in the Kiturami heating system, and repair in this case becomes inevitable;
  • error “08” warns that the route between the boiler and the temperature sensor is very long or a wire break has occurred in some place. Repairs will be required to identify the immediate cause of the operational failure;
  • error “95” means the pressure in the heating circuit is too low. The Turbo boiler needs to be energized and the entire heating system inspected for possible leaks;
  • error “96” - the mechanism that protects the Turbo system from overheating has activated;
  • error “98” - indicates that there is a lack of fuel in the supply line.

Of all the errors described above, “01” blinks most often on the display, but this does not pose a great danger to the operation of the equipment. The Kiturami Turbo 17 diesel boiler is characterized by maximum efficiency. Thanks to the control panel, the boiler control functionality is achieved and room heating is possible in any temperature regime.

In Turbo it is possible to regulate temperature parameters step by step from 45 to 75°C. All information about the operation of the diesel Kiturami Turbo is displayed on the thermostat screen by a self-diagnosis mechanism.

Most often, the Kiturami diesel boiler produces error 01. This happens when there is no stable ignition in the Turbo.

The reasons may be as follows:

  • when the screw jams, which serves as a fuel level limiter. The repair consists of replacing the locking element or checking the injection motor;
  • when the injection motor fails. It is necessary to check the working condition of the Kiturami motor. If the motor is faulty, then the repair consists of replacing it with a new one;
  • when there is not enough incoming fuel, then the level in the tank should be checked; repairs in this case will not be necessary;
  • when a foreign object accidentally ends up in the screw gate, it must be removed during the repair process;
  • when the photosensor fails, the Turbo repair consists of checking this element for its functionality.

When error code “01” periodically appears on the display, in such cases it is necessary to seek help from the appropriate specialists in order to avoid major expensive repairs.

Carrying out regular maintenance and repairs of Kiturami is a guarantee that Turbo boilers will operate efficiently and reliably. If irreparable damage occurs to a diesel boiler during the warranty period, it will be repaired without the need to pay for such work.

The Kiturami Turbo diesel boiler has excellent characteristics, but you must always remember that failure to comply with the established installation diagram, correct settings and basic rules for handling it in many cases ends in total repairs. If all requirements for use and operation are met, modern technologies for the production of heating equipment Kiturami guarantees each user stable operation of the boiler without the need for repairs and a long service life.

What are the differences between Kiturami heating boilers and what can cause them to break down?

The species diversity of Kiturami boilers affects the troubleshooting technology, so consideration of the types of their energy supply and design features is very important.

According to the type of fuel used, Kiturami boilers are divided into:

  • diesel (Turbo, KSO series);
  • gas (Twin Alpha, World Plus, KS);
  • biofuels (KRM).


Construction of a gas double-circuit boiler Kiturami Twin Alpha

In addition, the company also produces solid fuel (KF), condensing heating boilers that can operate on combined fuels. Regardless of the type of device, they all have similar equipment, which includes 5 levels:

  • an air system, which includes a chimney and inlet;
  • hydraulics, whose main function is to perform heat exchange of the coolant;
  • automatic control, with sensors and regulators;
  • the fuel system, through which the fuel enters the injector and is transferred by the pump;
  • electrical component.

All these levels interact with each other and provide the technical component (passport) of the device, so they must work uninterruptedly. That is why, if problems are detected, repair of Kiturami boilers must be carried out comprehensively. After all, even if the gear panel sensor shows a system failure, it will not indicate the real reason for the deviations in operation: be it a lack of grounding or a simple lack of fuel.

The main causes of problems include:

  • violation of operating rules;
  • incorrect installation;
  • depreciation of equipment;
  • untimely service.

Error codes and malfunctions of Kiturami gas boilers

The operation of gas equipment does not always occur without breakdowns. Therefore, manufacturers have developed a self-diagnosis system. Special sensors monitor the operation of each unit in the structure. In the event of a breakdown, error codes for Kiturami boilers are displayed on the display. Each symbol indicates a specific breakdown. We will show you how to deal with the problem yourself.

Design and principle of operation of Kiturami boilers

The Korean brand "Kiturami" produces powerful heating equipment. The devices can compete with other famous brands. The model range is represented by mounted and floor-mounted units.

Wall-mounted boilers are attractive due to their compact size. They can be placed in any non-residential premises: kitchen, corridor. Floor-standing options require a separate room (boiler room). But you can count on high performance.

High power - from 13 to 470 kW - allows Kiturami equipment to heat residential and industrial premises.

Models differ in the type of combustion chamber. The closed type is connected to a coaxial pipe, which is led outside through a hole in the wall. The turbocharged burner takes air from the street, and the built-in fan forcibly removes the smoke outside.

The open chamber is connected to a stationary chimney. The flame in the burner is maintained by drawing air from the room.

Based on the number of circuits, Kiturami offers single- and double-circuit models. Devices with one circuit work exclusively to heat the coolant for heating. Double-circuit ones provide hot water supply (DHW) and heating.

Read more about this on the page: “Review of Kiturami gas boilers.”

Errors and malfunctions

What to do if there is an error on the display? Look at the instructions. Usually the manufacturer indicates the decoding of the values. Another thing is that it is not always clear to the user. We will tell you how to fix the problem.

Error codeWhat does it meanHow to fix it yourself
01No ignition.
  • Open the gas supply valve all the way.
  • Bleed excess air from the system. For this you can use Mayevsky cranes.
  • Provide proper grounding.
  • Make sure there is normal gas pressure in the line. If not, then wait until the supply is restored.
  • Clean the burner from soot and dust.

Also run diagnostics:

  • Ignition wiring.
  • Electrode. If its contacts are clogged, clean them with fine sandpaper. Make sure that the ignition electrode is at a distance of 3 mm from the burner.
  • Gas supply valve.
  • Photocell flame control.
  • Electronic board.

Defective parts must be replaced.

02A false flame signal is received.Things to check:
  • Functionality of the photocell.
  • Control module connections.

Make sure there is no short circuit (short circuit) between the electrode and the module.

03In one minute the flame went out three times.Run diagnostics:
  • Operation of the fan and its motor. Inspect the wiring for integrity, tighten the contacts.
  • Flame sensor. Install the new part.

Look into the chimney shaft. If clogged, clean it from soot, debris, and dust. Open the window in the room if you are using a model with an open chamber.

04Thermal sensor problem.
  • Reboot by pressing the "Restart" button.
  • Inspect connections. Clean if oxidized or corroded.
  • Test the sensor with a multimeter for a short circuit or open circuit. Replace the faulty element.
05The overheating thermostat has failed. Some boilers include a seismic sensor. During an earthquake, it blocks the operation of the device. Check it for serviceability.

Remove scale from the heat exchanger. Remove it from the housing and wash it with a reagent. Use citric acid at home. Turn on the power supply.

06There is no connection with the fan operation. Inspect the fan blades, wiring, and connection tightness. Check the differential relay, its contacts for sticking, and the Hall sensor.

If there are voltage surges in the network, connect a stabilizer.

07Problems with the combustion products exhaust system.Run diagnostics:
  • Fan. If it runs at too high or low speed, replace it.
  • Outlet pipes. Condensation often accumulates in the folds and must be removed.

It is important that the height of the chimney pipe be maintained: 50 cm or more from the roof ridge. On a flat or combined roof 1-2 meters. Otherwise, the wind will blow out the flame in the burner.

08The length of the thermostat wire exceeds the permissible standards (over 10 meters). Or the wire is in contact with the telephone line. When laying, use a special cable. It should not be located near the AC cable.
Error 95The pressure in the heating circuit has dropped.How to proceed:
  • Clean the filters to remove clogging.
  • Inspect pipes, connections, and components for leaks. If damage is found, seal it. Also check the integrity of the heat exchanger and expansion tank.
  • If the tank membrane is deformed, replace it.
  • Add coolant to the circuit.
96Boiler overheating. Remove any scale from the radiator tubes.

Run diagnostics:

  • Pump, impeller unlocking.
  • Thermostat for open circuit and short circuit.
  • Main module.

Defective elements must be replaced.

97Fuel leak. Air accumulation in the system. Immediately turn off the fuel supply and contact the gas service.

Malfunctions of WORLD 5000 models

When the device is turned on and the CTR-5700 controller is started, the device does not respond. The lights don't come on and it doesn't start.

  • Make sure there is voltage in the network. Plug any equipment into a power outlet.
  • If it works, inspect the boiler; if not, then call an electrician.

The CTR-5700 external regulator is functioning, but the batteries are cold.

The coolant probably does not move well through the system:

  • Open the fuel valve.
  • Make sure the circulation pump is working properly.
  • Adjust speed settings.

Diesel boilers Kiturami

With fuel prices constantly rising, diesel boilers are in high demand. The best-selling models are the Kiturami boilers of the TURBO series. TURBO 13R or 17R boilers are very economical to use, fuel consumption is 8 liters per day. It is better to place the fuel tank of these boilers nearby, and more powerful boilers (from 35 kW) are equipped with special pumps, which allows the tank to be installed in another room. Also, more powerful boilers have the option of replacing the diesel burner with a gas burner.