Home / Gas boilers
Back
Published: March 26, 2020
Reading time: 5 min
0
7168
Korean Navien gas boilers are characterized by the highest degree of reliability. They work for many years without bothering the owners with breakdowns.
This is confirmed by user reviews and conclusions by heat power specialists, which can be found on the Internet in the public domain. Malfunctions of Navien boilers are quite rare.
This modification of heating units has good software diagnostics, so it will not be difficult for the user to understand the causes of failures and understand what to do to eliminate them.
- 1 Causes of malfunctions of Navien boilers
- 2 Self-diagnosis of Navien boilers
- 3 Error codes and how to fix them 3.1 Error 03
- 3.2 Error 02
- 3.3 Error 10
Causes of Navien boiler malfunctions
Any malfunctions of Navien boilers that are under warranty must be carried out by a service organization.
Before visiting a service organization, the consumer needs to turn on the diagnostic system, analyze the probable causes of the failure and evaluate the possibility of repair.
Error codes in Navien boilers are classified according to 3 structural elements:
- leaks in the heating circuit;
- the ignition system does not work;
- low parameters in the gas network.
Not all errors require the participation of service specialists. For example, the absence of a torch in a piezo igniter can be caused by a failure of the primary flame sensor, zero gas fuel pressure in the line, when the head valve is mistakenly closed, or in the event of a faulty ground loop.
Therefore, troubleshooting begins with inspecting the primary sensor, which must be clean and without damage. After cleaning the surface of the primary sensor, the boiler operation is checked again.
Procedure
Reboot
First you need to restart the gas heater using the mains switch using the remote control. The South Korean company's products are resistant to unstable voltage, but if its value deviates significantly from the nominal voltage, a false fault may be displayed.
Remote control boiler Navien
If the reboot does not produce results, then the problem is in the device itself.
Checking signal lines
The malfunction is easily identified by visual inspection after removing part of the housing. Error 13 can be caused by:
- melted insulation;
- unreliable contacts;
- short circuit;
- broken wires.
Inspection and troubleshooting will take very little time.
Self-diagnosis of Navien boilers
The self-diagnosis system guides the user to timely identification of faults in Navien. The electronic unit interrogates all sensors, analyzes the received data, and displays critical failures on the LCD display in the form of digital symbols. Practical guidance on troubleshooting is given in the technical documentation.
With the latest digital modifications, the monitor is located on the control panel. The codes are clearly visible even in the dark, due to the presence of bright multi-colored LED backlighting.
For different Navien boilers, information is presented in both digital and alphanumeric characters. There is absolutely no difference between failure “10” and “E10”.
Error 09
These fault codes are the most common. They signal that the fan has reduced its efficiency or has stopped. To accurately determine the cause, the integrity of its windings and the continuity of their resistance are checked. It is also necessary to make sure that there is an interturn short circuit. If the damage is serious, it is better to change the device. If no problems were found on the fan, you should ring the control board. This procedure will require certain skills: if they are absent, it is better to seek help from specialists from the service center.
Error codes and how to fix them
Let's look at the most common mistakes in the video. For this, many thanks to the Repair-31 channel.
Error 03
Error 02
Error 10
Automated self-diagnosis complexes, in combination with boiler protection systems, prevent the most serious breakdowns almost at the initial stage. When detecting a particular malfunction, the program turns off the boiler and displays a code on the LCD display.
The most common failures of Navien boilers:
- E01 indicates overheating of the coolant in the boiler unit. For atmospheric ATMO models, the electric pump does not function, since in these modifications there is no heating medium flow sensor, so the pump will need to be replaced. You must first check the operation of the heating system for airiness and the presence of contamination in the filter installed in front of the boiler unit.
- E02 indicates a network water circulation error. Error 02 on the Navien boiler is eliminated by checking the circuit for leaks. The pressure in the network is set from 1 to 2 bar; if necessary, the network must be recharged. Check the operation of the shut-off valves and three-way valve; they may be blocked. Check the operation of the flow sensor. If after these procedures the problem is not resolved, the board must be replaced.
- E03 indicates the absence of an electrical signal due to the presence of a flame in the firebox or a break in the primary sensor line. In the Navien boiler, error 03 is checked in the inspection window for the actual presence of a torch. If it is not there, check the electrical resistance of the coils on the gas line cutoff. Monitor the presence of a spark on the electronic ignition system and the gas pressure in front of the boiler unit. The torch may come off due to the large volume of air supplied by the fan.
- E04, false alarm due to flame in the burner. Error 04 on the Navien boiler is possible due to a leak in the gas shut-off valve or a spark from the ignition system is supplied to the flame sensor. The electrode unit will need to be replaced. If the problem persists after this, the board will need to be replaced. You will first need to check the grounding in the boiler with a resistance limit of at least 4 ohms.
- E05, error 05 - there is a break in the return temperature sensor line or its temperature is less than 14 C. Before carrying out repairs, check the humidity at the sensor connection.
- E06, error 06 - short circuit in the return temperature sensor line or its temperature is above 120 C. Check the electrical resistance of the sensor: 20 C - 10.0 kOhm, and 50 C - 3.6 kOhm. If the value is not normal, the sensor will need to be replaced.
- E07, violation in the DHW sensor line. A similar sensor check as above is needed.
- E08, short circuit in the DHW sensor line. A similar sensor check as above is needed.
- E09, error 09 - fan malfunction. You will need to check the incoming voltage on the board in the inclusion zones of the black and red conductors. If the voltage parameters are normal, but the rotation speed is low, less than 420 rpm, it is necessary to replace the electric fan, since ignition will not occur. If the electric fan speed is 2100 rpm. and the failure is not resolved, most likely there is a short circuit in the triac line; the electronic board must be replaced.
- E010, error 10 confirms a failure in the smoke exhaust circuit due to clogged smoke exhaust channels. It is necessary to inspect and clean the chimney, and pay attention to the air intake grille to see if it is clogged with foreign substances.
Troubleshooting other errors
Let's see how to repair a Navien wall-mounted boiler with your own hands or bring a floor-standing model to life. To do this, we will briefly go through the above error codes and identify troubleshooting algorithms.
Navien boiler shows error 01
Do not panic, as the reason for the display of this code may be a simple airing of the system and filter. It is necessary to bleed air from pipes and batteries using standard recommendations. The next step is to check the integrity of the circulation pump. Make sure that it is spinning and that its impeller is moving coolant through it normally. Sometimes an error occurs due to a physical breakdown of the impeller. The worst thing is if the circulation pump fails - in this case you will have to send it for rewinding or even purchase a new model.
In order to avoid problems with the circulation pump, we recommend purchasing a suitable model from the Grundfos brand.
Error 04 in Navien boilers
We have already talked about malfunction code 02 - it manifests itself as a rapid increase in temperature followed by its drop. We also dealt with code 03. If the self-diagnosis system displays error 04, you need to check the condition of the flame sensor and its circuit. Make sure the sensor does not touch other metal parts. Sometimes the appearance of this code is associated with a malfunction of the system board; it will need to be repaired or replaced.
Most often, control boards are replaced rather than repaired. If you have doubts about its performance, contact a specialist.
Errors 05 and 06 in Navien boilers
Also check the condition of the connecting wires - they should not be shorted or broken. For diagnostics, use the most common ohmmeter.
Here we need to diagnose the water temperature sensor in the heating circuit. Find data on its standard parameters, make sure they correspond (resistance to a certain temperature).
Errors 07 and 08 in Navien boilers
Double-circuit boilers give us heat and hot water. They are equipped with two circuits and two sets of sensors. For example, there are two temperature sensors here. One measures the temperature in the heating circuit, the other measures the temperature of the hot water. And the codes presented above indicate a breakdown of the temperature sensor of the DHW circuit or a malfunction in its circuit. Diagnostics and repairs are carried out in the same way as in the previous section - using an ohmmeter and visual inspection.
Eliminating errors 09 and 10
Here are typical fault codes for the Navien Ice boiler, indicating problems with the fan. It is necessary to check the integrity of its windings and test their resistance, to diagnose the presence of an interturn short circuit. A broken fan must be replaced with a new one. If the fan turns out to be intact, you should test the control board - do it yourself if you have the appropriate knowledge, or call a specialist from the service center.
As for error 10, it indicates difficulties in the operation of the smoke removal system. The fan may be to blame here; you also need to check the length of the chimney and make sure it is passable - cleaning will be required. Often the culprit is incorrect operation of the air pressure sensor. The worst thing is if the error appears as a result of constant failures in the Navien boiler board. The simplest wind blowing into the chimney cannot be ruled out.
Error 13 - problem with the flow sensor
This code is typical for Navien Ice and Navien Ice Coaxial boilers. It appears when there is a short circuit in the sensor circuit, and also indicates problems with its performance. The sensor must be tested and, if faulty, replaced. We also check the connecting wires. In rare cases, the control board is at fault.
Error 16 in Navien boilers
This code appears when the heating equipment overheats. There can be many reasons here:
One of the rarest causes of this error is an increase in the gas supply level. Check this parameter and tighten the valve if necessary.
- For some reason the coolant overheated;
- There is not enough coolant in the circuit;
- Control board malfunction;
- Malfunction of the three-way valve;
- The temperature control sensor in the DHW circuit is broken.
Carefully check all components and localize the fault.
Error 18 in Navien Ice atmospheric boilers
This code indicates overheating of the temperature sensor in the smoke exhaust system. When it is triggered, the operation of the equipment is suspended. We check the passage of the chimney, check the sensor itself and the connecting circuits, and make sure there is no backdraft. It is also possible that the control board may not operate correctly, but this only happens in the rarest cases.
Error 27 in Navien boilers
The last code in our review indicates a malfunction in the air pressure sensor circuit in the Navien Ice and Ice Coaxial models. We check all connecting wires and change the sensor if necessary. As in all of the above cases, a code may appear if the control board is not operating correctly.
Review of less common errors
There are other less common failures that indicate malfunctions in the operation of Navien boiler units and the need for repairs:
- E011, violation of the established parameters for the level or pressure of the medium in the heating circuit. This failure appears on the LCD display of a unit with an automatic water supply system. To eliminate the breakdown, it is necessary to disconnect the heating system, diagnose the functionality of the water make-up valve, drain the residual water in the electric pump drain, reconnect it and start the boiler again.
- E012, error 12 - no flame in the boiler furnace. There can be many reasons; it is recommended to use the elimination algorithm as for errors E003-E004. First check whether the main gas valve is closed, there is voltage in the boiler supply line and whether the grounding system is reliable.
- E013, error 13 characterizes a short circuit in the line or no power supply to the heating circuit flow sensor.
- E015, error 15 - malfunction of the control board. In the event that there is no response to the supply of electricity, repair or replacement will be required.
- E016, error 16 indicates overheating of the element in the system. Any component can overheat: the electric motor of the blower fan, the heat exchanger, the electric motor of the centrifugal pump. You can independently clean the installed filter in front of the boiler, the heat exchanger and replace the thermostat.
- E017, failure caused by a DIP switch, you will need to adjust the control board options and restart the boiler.
- E027, error 27 - failure of the primary pressure sensor. Check the blockage, the smooth operation of the sensor and the blower fan. If a breakdown is detected, replace the faulty part.
- E030, excessive heating of the smoke thermostat. It is necessary to turn off the boiler unit, allow time for it to cool for at least 30 minutes, after which the unit is restarted. If the failure is not resolved, check the blower fan and the primary air pressure sensor, and clean the smoke ventilation system.
- E 093, “on/off” button is faulty It can be replaced with your own funds.
Diagnostics of malfunctions and errors in gas boilers Navien Ice
_______________________________________________________________________________
_______________________________________________________________________________
Error code 02 - Indicates insufficient pressure inside the system. Possible causes that influence the formation of this problem: a decrease in coolant pressure in the heating system. The contact between the minimum pressure sensor and the electronic board is broken. Minimum pressure switch faulty. First you need to look at the pressure gauge readings. As a rule, the problem can be eliminated by using a feed tap, which is installed to supplement the system with coolant. If the accident recurs, then most likely there is a fluid leak. The hydraulic pump, primary heat exchanger, safety valve, damaged seals and gaskets, make-up valve and other parts may be leaking. Leakage is determined visually by inspecting hydraulic connections and components. Error code 03 - Indicates that there is no ignition. The flame ionization sensor signals a malfunction of the device. This sensor-electrode analyzes the presence of a flame and stops the operating functions of the Navien Ace gas boiler during incomplete combustion of the main burner or when there are difficulties with the gas supply. The operation mode stops after 3 unsuccessful starts. To resume operation, you must hold down the R button. Problem with the gas valve - The operation of the gas valve is controlled by an electronic board. This element is checked by measuring voltage and resistance. If it is found that the values deviate from the standard parameters, the valve must be replaced with a functional one. Lack of gas flow into the device - There is a valve in the gas distribution circuit that limits the gas supply. Based on this, a failure at the moment of starting the unit may occur due to a closed tap. Insufficient contact or the pulse from the flame control sensor was not detected. The control board has a malfunction - If ignition is carried out correctly, but the unit immediately goes out, then most likely the electronic board cannot see the flame. Based on this, it is recommended to test it. Error code 05/06 - The temperature sensor on the heating circuit is not functioning correctly. This situation indicates that the temperature sensor of the heating system is broken or the permissible temperature is too high. Damage to the heating circuit temperature sensor circuit - This problem most often occurs if the contact of the temperature sensor with the electronic board is interrupted, or the temperature is below normal. 5 seconds after recognizing the failure, the Navien Ace boiler should resume normal operation if the problem occurred spontaneously. It is recommended to make sure that there is no moisture on the sensor connector and the control board connector. If there is no moisture, the temperature sensor must be replaced. There is a short circuit in the heating water temperature sensor - This malfunction can occur when there is a short circuit in the temperature sensor circuit or the temperature of the water is higher than normal. First you need to measure the resistance of the sensor. If the resistance readings differ from the nominal ones, it is recommended to change the sensor. If installing a working sensor does not produce results, replace the control board. Error code 07/08 - Failure to detect the temperature by the DHW sensor. This circumstance indicates that the temperature sensor of the hot water supply circuit is broken or the required temperature has risen. Possible reasons for which this problem appears: the hot water temperature sensor is broken. Poor contact between the DHW temperature sensor and the control board. Control board faulty. If the hot water temperature sensor is intact and correctly connected to the electronic control board, although the device generates an error, then most likely the electronic board is damaged. Code 09 - Problems with the fan - There is a blockage in the fan impeller. There is no lubricant on the fan shaft, and therefore it does not reach the required speed. There is no contact between the electronic board and the fan. Error code 10 - Insufficient traction. For the correct and uninterrupted operation of the gas unit, it is necessary to create a draft to remove combustion products so that they do not enter the room. The exhaust of gases is controlled automatically, and when certain problems occur, the draft sensor-relay turns on and the boiler stops working. Probable reasons for the lack of draft: limited size of the chimney channel, inaccuracy during installation, blockage, icing of the inner wall. Limiting the size of the smoke exhaust duct causes insufficient draft. The chimney pipe is too long - You must carefully study the instructions for use of the appliance and follow the relevant requirements. A horizontal section of the chimney pipe that is too long can cause a lack of draft. Malfunction of the pressure switch-traction sensor - When a vacuum is applied to the supply tube, a faint click will be noticeable. There is poor contact between the traction sensor-relay and the electronic board, there is condensation, as well as incorrect connection of the tubes to the pneumatic relay. Error code 12 - Problems during ignition. This is displayed when there is no ignition or the burner flame goes out. It is necessary to diagnose the contacts between the ignition unit and the flame electrode, as well as between the board and the gas valve. The main factor in the attenuation of the burner flame may be a lack of draft. Code 13 - Malfunction of the heating / hot water flow sensor. Error 16 - Overheating of the heat exchanger of the Navien Ice boiler. The unit is blocked. The overheating safety thermostat has come into effect - The overheating thermostat, like the temperature sensor, is most often located on the outlet pipe of the primary heat exchanger. The main task of the thermostat is to protect the boiler unit from unnecessary temperature increases. An emergency occurs due to problems in the thermostat, temperature sensor, as well as when there is a malfunction in the main circulation circuit. Damage to the temperature sensor - The electronic board receives an incorrect signal or the contact between the sensor and the electronic board is broken. Failure of the overheating thermostat - When the component is operational, although actual overheating of the liquid is detected, then most likely there is a problem with the circulation of the heating circuit coolant. The primary heat exchanger or heating circuit filter element is clogged (low circulation levels suggest increased heating of the coolant). The circulation pump is broken or there is an air blockage in the heating system. Navien Ace 24K wall-mounted boiler in operation. Over the last week, it has started to show error code 03 (ignition) almost every day. After resetting with the reset button, the boiler sometimes turns on well, but this happens sporadically. Just recently I removed the air cap and it started working much better. What could be wrong? If it gives an error related to the chimney, be sure to open the protection covers. This will help draw air from the room. After this, inspect the chimney pipe for ice and, if necessary, clean it. If the accident is related to combustion, you need to find out whether gas is flowing into the house. Often the boiler displays error code 05. Can’t figure out what it signals? This code indicates a problem with the temperature sensor of the heating system. It probably needs to be replaced. Why does the Navien Ice 24 gas boiler not start? And it also periodically displays error 16. What should I do? Such a malfunction can appear due to various problems with the thermostat, temperature sensor, and also if there is a problem with the main circulation circuit. The heat exchanger is probably overheated. If the temperature sensor and thermostat are operational, then the problem is in the control board. We recommend that you replace it. Why can’t the boiler start up and error 02 is displayed? The pressure in the system is normal, there are no leaks. I unplug it, but the problem remains. Help, how to fix it? A fault code is usually issued when the coolant pressure in the heating circuit is low. If this problem occurs, we recommend checking the pressure sensor. It looks like it's broken. The malfunction of the device looks like this: the hot water supply is adjusted to a temperature of forty degrees. If you open a hot water tap, the gas burner lights up for a few seconds and quickly goes out. This process occurs regularly. Either warm water or cold water flows out of the mixer. Error code 16 often appears. Why did this happen? This code means that the DHW system coolant has boiled. The heat exchanger is probably clogged, or the thermostat is not set correctly. The following fault has occurred. During ignition, the device displays error code 12 (flame loss). When we reboot, it turns on, but as soon as the burner ignites, you can hear some clicks, and the error is shown again. I replaced the ionization electrode, washed the flow sensor, turned the plug over, but the result was zero. What could it be? This malfunction can occur in three cases. Damage to the flame control electrode. Difficulties with gas supply. The control board is damaged. The device spontaneously interrupted operation and issues code 02. What can be done? Low coolant level in the device or defective pressure switch sensor. First fill the system with water. The gas appliance stops working with error code 10. Cleaning and purging helped for a short time. What to do? This situation indicates weak draft, and the flue gas exhaust system needs to be checked. The membrane may have stuck. Otherwise, it is necessary to call a specialist for a thorough inspection of the gas boiler and then follow it up. The home operates a Navien Ace 13K gas wall-mounted boiler. An error with code 08 began to appear. The unit itself is doing the work, the coolant temperature level is set by a manual switch. During its installation, it probably overheated, since the automatic temperature mode was turned on. There is no outdoor air temperature sensor. For what reason did this happen? Most likely, the hot water temperature sensor has broken down. Sometimes the control board fails. The unit works for about 2-3 minutes, then the burner device turns off, and error 10 occurs. It burns for no more than a minute, the gas burner starts working again, and the unit functions uninterruptedly for another 3-4 minutes, and so on continuously. This failure, judging by the manual, indicates that the draft sensor is triggered, although the chimney channel is not clogged, combustion products come out normally. I just can’t figure out what is causing the problem? In your case, the main sources of lack of traction may be: a malfunction of the traction sensor pneumatic relay. There is no contact between the air relay sensor and the electronic board. Condensation in the tubes, as well as incorrect connection of the tubes to the pressure switch. There is a problem with the fan. It may be running at low speeds.
_______________________________________________________________________________
_______________________________________________________________________________
- Gas boilers
- Electric boilers
- Boiler error codes
- Troubleshooting boilers
- Gas water heaters
- Malfunctions and repairs of geysers
- Water heaters
- Troubleshooting water heaters
- Repair of indirect heating boilers
- Troubleshooting electric convectors
_______________________________________________________________________________
- BAXI ECO FOUR
Heating system control. Installation. Connection. Transfer to another type of gas. Adjustment devices and protection devices.
- BAXI LUNA
Peculiarities. Installation and assembly. Automation components.
- BAXI MAIN FOUR
Technical specifications. Installation. Adjustment and checking. Maintenance.
- BAXI SLIM
Adjustment and protection. Installation and assembly. Pressure setting. Maintenance.
_______________________________________________________________________________
_______________________________________________________________________________
- BAKSI - REPAIR
After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again. It turned on once, but it gives error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me, what could it be?
- BAXI - OPERATION
In operation, the Baxi main four 240 boiler shuts down with error E35 (stray flame). Tell me what to do? First season in operation.
- BAXI - SETTINGS
We installed and connected the Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW device?
- BOSCH - REPAIR
Bosch 6000 24 kW boiler, single-circuit with built-in three-way valve. The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler?
- BOSCH - ADJUSTMENTS
If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3?
- ARDERIA - REPAIR
We installed an Arderia esr 2.13 ffcd boiler. If my coolant pressure drops slightly by a couple of notches over 2-3 days, could the reason be a faulty three-way valve (there are no leaks from the radiators)?
- ARDERIA - ADJUSTMENTS
The gas boiler Arderia 2.35 is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power?
_______________________________________________________________________________
- BUDERUS FLOOR
We installed and connected the Buderus Logano G234-WS-44 kW boiler, automatic Logomatic 4211. Heating is based on cylinders without hot water, and the jets for reduced gas were also replaced. We survived the winter, the cylinders were replaced, all without problems. Then in the spring, when the outside temperature was +16+18, the boiler began to turn off for a long time and when turned on, it began to display a burner error on the screen and the red button light on the front wall came on. We pressed the button, turned the power back on and everything worked. This happened several times, then the boiler was turned off completely for the summer, what could be the problem?
- BUDERUS WALL
In the single-circuit Buderus 072, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on the 2-circuit one that is used for DHW?
- VAILLANT - REPAIR
Tell me, for Vaillant wall-mounted gas boilers, are there real/actual differences for the better in the new generation turboTEC plus VU/5-5 compared to /3-5?
- VAILLANT - ADJUSTMENTS
There is a malfunction in the boiler, the green LED (power) is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board. How to fix? I checked all SMD resistors and transistors, everything is fine.
- DAEWOO
In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer. I removed the three-way valve, there is no dirt or wear. It seems that the board does not control the three-way valve. How to check?
- ELECTROLUX
The Electrolux Basic Xi wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after 7-8 seconds. And after 3 attempts it gave error E1. How can I fix it?
- KOREA STAR
Koreastar boiler malfunction. The heating works perfectly, the hot water comes intermittently, when you turn on the hot water tap, cold water comes out first, then boiling water. After a few seconds it’s cool, then boiling water again. What could be the problem?
- FERROLI
Malfunction of the Ferroli Domiproject 24 boiler - I set it to 60-70 degrees, it switches to minimum combustion, does not turn on, does not turn off. Restart is unstable. No pattern emerges. What to do?
- JUNKERS
In operation, a Junkers euroline gas boiler, when hot water is turned on, gas ignites, then goes out, and so on several times. If you turn it on while the heating is running, the water heating starts immediately. Tell me, please, what could be the problem?
- NAVIEN
Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.3. It is not possible to adjust the fan run-on. I set it to 30 seconds, but still 2 minutes. spins.
- OASIS
Malfunction of the Oasis ZRT18 boiler. The unit starts, the gas lights up, then goes out. It lights up again and then goes out (this happens three times). Then it lights up and works fine. It doesn't give any error. What is the reason?
- SAUNIER DUVAL
Malfunction of the Senor Duval gas boiler - the water pressure sensor shows 0.0, the indicator flashes red, the hot water does not heat up, but the water pressure in the apartment is good. How to fix the problem?
- VIESSMANN
Where should a condensate trap be installed in a coaxial chimney? The boiler wh1d with a closed combustion chamber is located at a distance of 1 m from the wall.
- WESTEN
Problem starting the Westen Pulsar D boiler. Piezo ignition works, but there is no flame, error E01 after a crackling sound. I moved the fork around.
- BERETTA
The Novella floor-standing gas boiler is blocked - the green lights on the panel are on and nothing else happens. How to fix?
- ARISTON
An Ariston gas wall-mounted boiler has been installed and connected, which does not hold pressure at all: while cooling the heated water, the pressure drops to zero, although water is regularly filled. What about the pressure?
- SIME
Metropolis dgt 25 bf boiler malfunction. The hot water supply has stopped working, the heating is working, it does not display an error. What do you advise?
- SOLLY
Please tell me how to solve the problem. The Solly Standard boiler, whenever you try to turn it on or hot water, displays a GS error.
- WOLF
Wolf boiler in operation. Lately it has begun to behave strangely: during the pause between starts, it turns on the burner for one second five times, and 70 degrees appears on the display. Where to look for a problem?
- ACV
ACV Wester Line works very unstable: it often crashes, makes a characteristic knock and stalls when starting, but at times everything is fine. The unit is almost new, what's wrong with it?
- DEMRAD
In the gas boiler Demrad, the gas supply to the burner stopped. The piezo element clicks, but there is no ignition. There is nothing wrong with the gas stove, there is gas. What is the reason?
- KITURAMI
The Kiturami world boiler is malfunctioning and stops periodically. I clean the flame sensor and the unit works fine for a while, but soon the same thing happens again. He also began to smoke heavily. Maybe the problem is that the chimney is short, and it needs to be lengthened?
_____________________________________________________________
- IMMERGAZ - ERRORS
Errors of Nike Star, Eolo Star/Mini, Mythos boilers. Malfunctions of boilers with the possibility of automatic unlocking.
- IMMERGAZ - REPAIR
My boiler systematically raises the temperature to 80 degrees in winter mode. I called the repairman three times. He said that many models have this problem and suggested installing a programmer, but it’s not certain that it will help. Tell me how to solve this problem and will this programmer help?
- AOGV
Models 11.6; 17.4; 23.2; 29.3 kW. Specifications. Control elements of the automation unit. Installation and maintenance. Malfunctions and their elimination.
- AOGV - REPAIR
The AOGV gas boiler was installed and put into operation. Problem with hot water supply. The heat exchanger was washed. Less than a month has passed and the water is not flowing again. We put a filter on the water, but time passed, and again there was no hot water. What kind of breakdown could this be?
- AGV
Installation and installation. Start-up and adjustment. Malfunctions and ways to eliminate them.
- AKGV
Technical specifications. Installation and connections. Startup and operating procedure. Automatic adjustments.
- NEVA LUX
The boiler Neva Lux 7023 is malfunctioning. It gives error E7 twice a month. But after reboot it still works. Now it gives error E6. It will work for 15 minutes and turn off. What could it be?
- ROSS
Design and automation unit. Ignition order. Malfunctions and repairs.
- ATEM ZHYTOMYR
Tell me, is it possible that due to low gas pressure the Atem Zhytomyr boiler goes out, a click occurs and goes out. What is the problem? Is it possible to temporarily disable automation and how?
- LEMAX
We installed a Lemax KSG-12.5 Premium gas boiler. After turning off the main burner, a clicking sound occurs after a couple of minutes, what is the reason? Tell me?
- KEBER
A KS-G gas boiler of 250 sq.m. was installed and connected. m. When ignited, it does not turn off, the temperature rises, if I am not mistaken, automatic Arbat 1. The flame is not regulated - it is too large. What to do?
- LIGHTHOUSE
I installed the Mayak gas boiler and connected it. It works fine. But the reason is this. When it works on unit it squeaks a lot, if you turn the knob 2-7 the squeak disappears. Tell me, what could it be?
- DANKO
We installed and connected a Danko gas boiler with automatic Kare, it works great on the igniter, but as soon as you add power to the burner, it goes out completely, yesterday it went out within 5 minutes, today it works for about 20 minutes and goes out completely. Has anyone encountered this problem?
- GAZLUX
The gaseko 18 boiler is in operation. When hot water is turned on, the pressure in the system drops after replenishment, the pressure reaches 3 bar. Have to reset. What's wrong, how to fix it?
- NOVA FLORIDA
Water often boils in the boiler, causing it to fail due to overheating. The heat exchanger was recently washed, the system is not clogged. What's the matter?
- RINNAI
Rinnai 167 RMF boiler malfunction. Recently I started showing error 14. How can I fix the problem?
- CELTIC
The Celtic DS boiler heats up to 45 degrees and sits all day, does not turn off and does not heat the batteries, sometimes it shows error A3. How can I fix this problem?
- MORA
The hot water pressure in the Mora Top boiler has dropped. What is the reason?
- MASTER GAS SEOUL
The Seoul gas wall-mounted boiler stopped turning on due to a no-ignition error. How can it be eliminated? What exactly went wrong?