Errors in the Proterm Medved gas boiler - Causes and how to eliminate them


Error F1 on the Protherm boiler Proterm Bear

Error F1 on the Protherm boiler Proterm Bear

KLZ/ KLOM F1 Loss of flame This error means irreversible blocking of automatic ignition and cessation of gas supply through the gas valve, i.e. LOSS OF FLAME. Such a blockage can occur in cases where, being in the open gas valve mode, the ignition automatic system does not receive a feedback signal about the presence of a flame from the ionization electrode. The boiler will turn off and error F1 will appear on the display. This malfunction can also be caused by the activation of safety elements - an emergency thermostat or a combustion products thermostat. Low gas pressure at the inlet, incorrect electrical connection (phase and zero are reversed) can also cause loss of flame. To clear the fault, press the RESET button (Fig. 1, item 6). If the fault cannot be resolved using the RESET button, contact your service organization.

KLOM KLZ KLO

Error F1 means loss of flame. That is, the boiler does not see the burner flame when ignited. A similar blockage can occur in cases where the gas valve is open. , the automatic ignition system does not receive back a signal about the presence of a flame from the electrode. The boiler turns on, error F1 is displayed on the display. This malfunction can also be caused by the activation of the safety elements of the emergency thermostat, thermostat of combustion products, low gas pressure at the inlet. To start the boiler, you must press the error reset button @ Reset @ .

Error F1 on the Proterm boiler

Reset (designation “torch”) – pressing this button eliminates the flame loss fault. When the combustion products thermostat is activated, the button operates only after the thermostat has cooled, i.e. approx. after 10 minutes.

If the malfunction occurs again, it is necessary to identify and eliminate the causes of loss of chimney draft. If the reason is not obvious (dirty chimney), you must invite a service technician!!!

POSSIBLE OPTIONS WHY THE ERROR OCCURS

INSUFFICIENT GAS PRESSURE (OR INCORRECT GAS VALVE ADJUSTMENT)

  • Thermostat overheating
  • Contamination of the ignition electrodes

  • Rephasing Possibly incorrect mains voltage
  • Electronic control board is faulty

Check

  1. Gas valve
  2. Boiler control panel
  3. Ignition automation
  4. Distance between the western ends of the electrodes. You also need to check the cables
  5. Check boiler power parameter
  6. Check the gas supply to the boiler inlet
  7. Check phasing
  8. Check if the draft sensor is switched off if the boiler is in the chimney
  9. Check the emergency thermostat and restart if necessary.

Insufficient gas pressure (or incorrect gas valve adjustment)

You can check whether voltage is supplied to the gas valve. If the gas valve is turned on, it opens the passage. We check what gas pressure is at the inlet in statics and dynamics. If the gas pressure deviates from the indicators, then we adjust the gas valve. The gas line filter becomes clogged from time to time. “Recommendation to rinse” If gas cylinders are used to operate the Proterm boiler, a critical decrease in pressure may also occur. In this case, the pressure in the cylinder should be measured and replaced if necessary.

Water or Chimney thermostat overheating

The problem may also arise from overheating of the coolant. If there are no leaks, you need to fill the system with coolant and monitor the pressure in the heating system.

In some cases, a malfunction occurs. The temperature sensor itself. (It should be replaced)

Overheating is possible if the circulation pump does not work properly. , formation of an air lock, clogging of the heat exchanger or water filter.

If there is a sharp increase in the temperature of the flue gases, error F1 also appears.

Possible reasons for this situation are the lack of traction and a clogged channel. Various debris from leaves Also a bird could have gotten in (Not a rare case)

A common problem is an illiterate chimney diagram or violation of installation rules. An error may occur when changing the Wind Rose.

Contamination of the ignition electrodes

A common reason for an error to occur in the Proterm boiler. This is contamination of the ignition electrodes when the boiler has not been serviced for a long time (no maintenance has been performed) Re-phasing The mains voltage may be incorrect. To avoid this problem, when connecting the boiler, be sure to check where the phase and zero are and Apply a mark to the plug, for example with a felt-tip pen.

What to do if the boiler shows F?

This section lists all possible fault codes along with the corresponding corrective actions that the USER CAN perform to restore the equipment to operation (Corrective Action: ...). Other faults MUST only be repaired by a qualified technician.

Error messages are shown on the display in the place where the pressure value in the heating system is normally displayed. Along with the fault code, the telephone icon and the letter F with the corresponding error code flash on the display.

Under normal operating conditions, the 10 most recent error messages can be displayed on the display by pressing both buttons for setting the heating temperature at the same time for approximately 7 seconds.

Code Description
F0 NTC flow temperature sensor circuit open
F1 Return Temperature NTC Sensor Circuit Open
F2 DHW temperature sensor NTC circuit is open
F3 DHW tank sensor NTC circuit is open
F4 Manifold Sensor NTC Circuit Open
F5 Exhaust gas sensor circuit is open
F6 Traction sensor circuit is open
F7 Faulty connection of the NTC temperature sensor in the return line coming from the solar collector
F8 The NTC circuit of the DHW boiler ground sensor is open
F9 Hood Sensor NTC Circuit Open
F10 Short circuit NTC flow temperature sensor
F11 Short circuit NTC return temperature sensor
F12 Short circuit of NTC DHW boiler sensor Short circuit of NTC DHW temperature sensor
F13 Short circuit of NTC DHW boiler sensor
F14 Collector NTC sensor short circuit
F15 Exhaust gas sensor short circuit
F16 Draft sensor short circuit
F17 Short circuit NTC return temperature sensor from solar collector
F18 Short circuit NTC DHW boiler ground sensor
F19 Short circuit of NTC hood sensor
F20 The safety temperature limiter has tripped
F21 The boiler is blocked due to exceeding the threshold value
F22 The water level in the boiler is insufficient, the pump is blocked or faulty
F23 Low water level: large temperature difference between NTC sensors on flow and return lines
F24 Low water level: rapid rise in temperature
F25 Protection against leakage of combustion products into the room has activated
F26 Incorrect current value of the gas valve stepper motor windings
F27 The ionization device signals the presence of a flame, although the gas valve is closed
F28 Unsuccessful first attempt at ignition
F29 Loss of flame during burner operation
F30 Interlock sensor circuit open
F31 Blocking sensor short circuit
F32 Fan anti-freeze protection activated: fan speed is outside the permissible limits
F33 Fan anti-freeze protection activated: pressure sensor open Pressure sensor not open (when fan is not running)
F35 Error in the smoke removal system
F36 Draft diagnostics (only for models with exhaust of combustion products into the chimney)
F37 The fan speed during operation is outside the permissible limits
F38 The measured frequency exceeds the permissible limits
F39 Error in boiler autodiagnostics
F41 Incorrect gas regulation
F42 Coding resistor problem
F43 Incorrect boiler model identification
F49 eBus voltage low
F55 CO sensor error
F58 No feedback regarding preheat
F60 Error in gas valve control +
F61 Error in gas valve control -
F62 Gas valve disabled error
F63 EEPROM error
F64 AOC error
F65 Electronics overheating
F66 IIC data bus error
F67 Flame signal from ASIC is not reliable Diagnosed flame signal input is out of range (O or 5V)
F70 Incorrect OSN
F71 Hot water flow sensor is constantly open
F72 Constant difference in readings of the flow sensor and NTC return temperature sensor
F73 The pressure sensor is not connected or there is a short circuit in it
F74 Malfunction in the electrical part of the pressure sensor (or damaged wire)
F75 Repeated pressure sensor error. After starting the pump, no pressure surge was detected.
F76 Malfunction of the thermal fuse on the primary heat exchanger
F80 Input sensor SHE error
F81 Circulation pump error
F82 Faulty anode tester
F90 Not connected to APC module
F91 Sensor failure in APC module

Error F4 on the Protherm boiler Proterm Bear

False readings from the hot water sensor can cause such an error. This means that the sensor needs to be checked for a break; if the temperature sensor circuit is intact, then it is almost impossible to replace the temperature sensor; it is almost impossible to repair the t sensor. Check circuit/replace sensor.

Error F4 on the Protherm boiler Proterm Bear

F4 Boiler sensor malfunction The boiler will stop working to heat the boiler. This malfunction does not affect the heating mode.
  • Replace sensor
  • Check:
  • — sensor resistance
  • — cables connecting the sensor to the control panel.

Broken NTC sensor (thermistor) return temperature

Defect: NTC sensor, NTC sensor cable, NTC sensor plug connector, plug contact on the electronics unit;

Measured temperature

Error F5

Errors in Proterm floor units

If there is a problem with the Proterm Bear floor-standing gas boiler, error codes appear:

  1. F2 temperature sensor malfunction. This error indicates a breakdown of the temperature sensor or a decrease in the coolant temperature to 3ºC. The operation of the unit is blocked, since switching on at a temperature below 3ºC is not allowed by the manufacturer.
  2. F3 signals an increase in coolant temperature to 95ºC. In this case, the unit is blocked. It will resume operation after the liquid has cooled.
  3. F4 – boiler sensor failure. In this case, the unit does not heat the liquid in the boiler.
  4. F5 – external temperature sensor is broken. The unit remains operational, but the coolant temperature will be regulated by the boiler sensor.

You can try to reset the error code that appears on the screen for the first time by pressing the “RESET” key. If this does not help and you cannot determine the cause of the failure, call a specialist from the Proterm service center.

The Proterm brand has long been known on the Russian market: gas equipment regularly performs its functions for heating and hot water supply in both residential buildings and small industrial facilities. Sometimes equipment breaks down. If the reason is a manufacturing defect, then it is better to replace the boiler immediately, but minor problems can usually be eliminated on their own.

We will tell you how you can repair a Proterm gas boiler yourself, based on self-diagnosis data and the manufacturer’s recommendations. We'll show you how to identify a malfunction of equipment using the code. We will advise you on how to accurately determine the cause of the breakdown by decoding.

In the article we present you will find a description of the popular positions in the model range of boilers of this brand. Get acquainted with typical malfunctions in the operation of units for heating systems and methods for troubleshooting.

Rating
( 2 ratings, average 4.5 out of 5 )
Did you like the article? Share with friends: