The gas boiler in Zhytomyr goes out, what should I do?


Diagnostics of breakdowns and maintenance of Atem boilers

_______________________________________________________________________________________________________________

_______________________________________________________________________________

I ask for help to understand this issue. The house has an Atem 10 gas boiler with Eurosit 630 automatic control. After ignition, the main burner starts to burn perfectly, but after 10-20 seconds it turns off. Repeated action does not produce changes. Who has encountered this?

First check the functionality of the draft sensor and thermocouple. Check the circuit contacts. Carefully dismantle the pilot burner and vent it. Set the pilot burner to minimum gas pressure. There has probably been a deterioration in draft, and now the igniter has a lack of air at the time of ignition of the main burner device.

The flame smokes excessively and the burner always burns without going out. The temperature does not rise above a certain level, although the fire burns. There is a lot of soot in the boiler. The gas organization explained that there was poor traction. How can I fix the problem?

Most likely, poor air flow. Full maintenance is required. Dismantle the burner device, clean and rinse all components and parts. It is recommended to clean the heat exchanger from the outside.

Please tell me what the problem is if the boiler smokes? What should be done to fix this problem?

Apparently, there is a weak draft in the combustion chamber. You should have your chimney cleaned.

Tell me what to do if the Atem 15 boiler stops starting? I try to hold the control handle, press the ignition button, then I hold it for about five minutes, start pressing it, and the device goes out.

We assume that the ignition tube is dirty. If such a malfunction occurs, you need to perform maintenance. There may also be oxide on the traction sensor clamps. Disconnect the terminals and remove any deposits from them.

Malfunction of the Atem floor-standing boiler with gas valve 710 Minisit. When you press the igniter button, there is no gas supply to the gas burner device. What could have happened?

If you press this key, gas is supplied exclusively to the pilot burner, it does not enter the main burner.

We installed this device. I'm not happy with the switch from the igniter to the main burner. Several pops are heard. Could this be some kind of problem?

Most likely, you should adjust the automation to the recommended gas pressure.

We have a device of the same model, complete with automatic Minisit 710, which stops when heated to about 70 degrees. Am I asking for help to fix this problem?

The traction sensor may be turning on. It is necessary to inspect the chimney duct.

The same device is installed in the house. The other day it failed at heating at 50 degrees, but the fire continues to burn steadily. What could have happened?

Apparently the gas supply pipeline from the automation unit on the burner, as well as the burner nozzle, was clogged with soot.

In our house there is a single-circuit heating boiler Atem Zhitomir 3 KS-G 012 with Eurosit 630 automation. A week ago it developed a problem. It goes out if wind blows on the igniter. I replaced the thermocouple several times, but it did not help. What reason?

When the main burner turns on, this causes a decrease in the fuel supply to the pilot burner, so the safety automatics are activated. You need to increase the gas supply to the ignition mechanism. This can often happen due to a decrease in pressure in the heating system. There may also be a lack of chimney draft if it is installed incorrectly.

Tell me why this model sometimes stops working, mainly when there is wind and bad weather outside. How should the problem be solved?

When you turn on the pilot burner, the EMC valve should operate within twenty seconds. When the pilot burner goes out, the EMC valve function will be interrupted in a 10 second cycle, at which point a clicking sound will be heard.

Four years ago, the Atem Zhitomir 12 boiler was installed in the house. The house is small, the space is no more than forty meters. As if the need is small, although the water does not heat above 55 degrees. The house has 2 batteries for 10 sections. I just don’t understand how to raise the heating temperature?

To correct the situation, install a circulation pump. The pressure in the gas line may often drop.

For what reasons does the boiler often overheat during operation?

The main factor is the loss of circulation in the heating circuit. It is also possible that the filters are clogged or there is an excessive amount of air in the heating system.

There was a problem yesterday. If you close the cold water valve and open the hot water tap, all the water leaves the heating circuit. What's happening?

It looks like the heating system fill valve is not working properly. It passes water through both pipelines. When there is coolant pressure in the system, then passage in the opposite direction cannot happen.

For what reason does the device make noise, gurgle, and at times howl for a long time and clap loudly?

The liquid in the system is very enriched with oxygen. When heated, air bubbles are released, causing you to hear noise. If the device is adjusted incorrectly, the gas valve or bypass valve howls. Strong pops during startup indicate a problem with the ignition.

In October of that year, I launched the Atem 12 floor-standing gas boiler. About six months later, a problem arose. I'm trying to adjust the temperature, but it doesn't hold it. Explain what is the reason?

It is possible that problems have arisen with the automation, and when the temperature rises by 65 degrees, the nozzles turn off. It is necessary to adjust the automation to perform the functions correctly. Another factor may be that the selected power of the device is inappropriate in relation to the heated area.

I launched the same device in early August. It runs on liquefied gas. Almost 8 m3 was spent in 3 months. Currently, there are a lot of soot deposits inside the unit, and the main burner is also smoking. Why is this happening?

A large amount of soot deposits in the combustion chamber indicates that the gas burner device is not adjusted and the gas is not fully burned. A low-quality grade of gas mixture is also possible. To avoid soot from the burner, it is necessary to carry out timely cleaning using water.

I had this device installed. During startup, the burner device lights up and immediately goes out. I believe the ignition spark is missing. How to delete this alarm?

You need to check if the igniter spark sound appears when the ignition cable is disconnected. If not, you must change the ignition transformer. If the sound appears, replace the igniter electrode or burner.

Just yesterday a problem arose with the Atem Turbo boiler. A water leak has formed. Was in use for a total of 3 weeks. Perhaps someone can tell me what is causing the leak?

Dripping may occur due to increased pressure in the system. There may be burnout of the heat exchanger walls. Water hammer can also be a factor in boiler leaks.

It is planned to install this device at the dacha. Please tell us what is the standard gas supply pressure (methane/propane) for such models?

In this type of equipment, the nominal gas supply pressure for methane/propane is 150.0/300.0 Pascal.

This device is connected to the system. Yesterday there was a problem with it. The boiler starts, but does not warm the room. What could it be?

Most likely, air has accumulated in the batteries or excess scale in the heat exchanger. It needs to be washed.

We use this unit at our dacha. Until now it has worked properly. It is currently experiencing a breakdown. The unit constantly overheats. How to remove this damage?

It is possible that scale has built up, resulting in a blockage of the duct. You need to clean the device.

The other day there was trouble with the heating boiler. It worked properly for a total of 3 months. After that, suddenly it stopped reaching the set temperature. Tell me why this happened?

The gas pressure in your system is weaker than necessary. We need to inspect the gas valve. It looks like there is too much lube inside. Just remove the excess.

Tell me how to pump up the expansion tank?

The expansion tank is pumped up with any available pump to the required pressure according to the passport. Basically, the norm is from 0.8 to 1.5 bar. To pump up the tank, according to the regulations, you need to drain the water from the boiler. This is done using a drain fitting or using a water tap, closing the hot water supply.

The Atem Zhitomir 3 KS-G 010 Sn floor-standing gas boiler does not start. When you hold down the start button, the burner works normally. But if you press the key, the device goes out. What is the cause of the malfunction?

The thermocouple has probably failed or there is a problem with the gas valve. There may also be low gas pressure in the inlet pipeline. In some cases, the control board voltage may be too low.

Remind us what operations are required to change methane to propane?

First, you need to change the nozzles of the main burner device. Then change the modulator supply voltage. When finished, adjust the pressure settings to maximum and minimum.

How does a heating system safety valve work?

This device, which is adjusted to the operating pressure, protects the heating system. It is not permitted to use the safety valve to drain water from the system.

The pressure of the heating system periodically increases. We reduce the pressure of the expansion tank to a limit of 2.1-2.3 atm. Is it possible that heating circuit water is leaking from the hot water system?

The increase in pressure in the heating system can be explained by 2 main reasons. The pressure for the expansion tank is poorly adjusted. The make-up valve is leaking.

We've got a problem. The launch is very bad. The igniter lights up, but the main burner has no fire. I just can’t understand what is the reason?

Apparently the ignition device is faulty. We advise you to service the unit and clean the ignition device.

Help me figure out the chimney pipe? For two days now, a return draft has appeared, due to which smoke began to pour directly into the room. We did the chimney ourselves. It is a steel pipe. There may be a discrepancy somewhere.

The main reason may be an incorrectly designed chimney. There may be soot contamination which severely limits its performance. In addition, it is necessary to control the ventilation openings in the room.

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

Heating system control. Installation. Connection. Transfer to another type of gas. Adjustment devices and protection devices.

Peculiarities. Installation and assembly. Automation components.

Technical specifications. Installation. Adjustment and checking. Maintenance.

Adjustment and protection. Installation and assembly. Pressure setting. Maintenance.

_______________________________________________________________________________

_______________________________________________________________________________

After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again. It turned on once, but it gives error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me, what could it be?

In operation, the Baxi main four 240 boiler shuts down with error E35 (stray flame). Tell me what to do? First season in operation.

We installed and connected the Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW device?

Bosch 6000 24 kW boiler, single-circuit with built-in three-way valve. The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler?

If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3?

We installed an Arderia esr 2.13 ffcd boiler. If my coolant pressure drops slightly by a couple of notches over 2-3 days, could the reason be a faulty three-way valve (there are no leaks from the radiators)?

The gas boiler Arderia 2.35 is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power?

_______________________________________________________________________________

_______________________________________________________________________________

We installed and connected the Buderus Logano G234-WS-44 kW boiler, automatic Logomatic 4211. Heating is based on cylinders without hot water, and the jets for reduced gas were also replaced. We survived the winter, the cylinders were replaced, all without problems. Then in the spring, when the outside temperature was +16+18, the boiler began to turn off for a long time and when turned on, it began to display a burner error on the screen and the red button light on the front wall came on. We pressed the button, turned the power back on and everything worked. This happened several times, then the boiler was turned off completely for the summer, what could be the problem?

In the single-circuit Buderus 072, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on the 2-circuit one that is used for DHW?

Tell me, for Vaillant wall-mounted gas boilers, are there real/actual differences for the better in the new generation turboTEC plus VU/5-5 compared to /3-5?

There is a malfunction in the boiler, the green LED (power) is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board. How to fix? I checked all SMD resistors and transistors, everything is fine.

In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer. I removed the three-way valve, there is no dirt or wear. It seems that the board does not control the three-way valve. How to check?

The Electrolux Basic Xi ​​wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after 7-8 seconds. And after 3 attempts it gave error E1. How can I fix it?

Koreastar boiler malfunction. The heating works perfectly, the hot water comes intermittently, when you turn on the hot water tap, cold water comes out first, then boiling water. After a few seconds it’s cool, then boiling water again. What could be the problem?

Malfunction of the Ferroli Domiproject 24 boiler - I set it to 60-70 degrees, it switches to minimum combustion, does not turn on, does not turn off. Restart is unstable. No pattern emerges. What to do?

In operation, a Junkers euroline gas boiler, when hot water is turned on, gas ignites, then goes out, and so on several times. If you turn it on while the heating is running, the water heating starts immediately. Tell me, please, what could be the problem?

Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.3. It is not possible to adjust the fan run-on. I set it to 30 seconds, but still 2 minutes. spins.

Malfunction of the Oasis ZRT18 boiler. The unit starts, the gas lights up, then goes out. It lights up again and then goes out (this happens three times). Then it lights up and works fine. It doesn't give any error. What is the reason?

Malfunction of the Senor Duval gas boiler - the water pressure sensor shows 0.0, the indicator flashes red, the hot water does not heat up, but the water pressure in the apartment is good. How to fix the problem?

Where should a condensate trap be installed in a coaxial chimney? The boiler wh2d with a closed combustion chamber is located at a distance of 1 m from the wall.

Problem starting the Westen Pulsar D boiler. Piezo ignition works, but there is no flame, error E01 after a crackling sound. I moved the fork around.

The Novella floor-standing gas boiler is blocked - the green lights on the panel are on and nothing else happens. How to fix?

An Ariston gas wall-mounted boiler has been installed and connected, which does not hold pressure at all: while cooling the heated water, the pressure drops to zero, although water is regularly filled. What about the pressure?

Metropolis dgt 25 bf boiler malfunction. The hot water supply has stopped working, the heating is working, it does not display an error. What do you advise?

Please tell me how to solve the problem. The Solly Standard boiler, whenever you try to turn it on or hot water, displays a GS error.

Wolf boiler in operation. Lately it has begun to behave strangely: during the pause between starts, it turns on the burner for one second five times, and 70 degrees appears on the display. Where to look for a problem?

ACV Wester Line works very unstable: it often crashes, makes a characteristic knock and stalls when starting, but at times everything is fine. The unit is almost new, what's wrong with it?

In the gas boiler Demrad, the gas supply to the burner stopped. The piezo element clicks, but there is no ignition. There is nothing wrong with the gas stove, there is gas. What is the reason?

The Kiturami world boiler is malfunctioning and stops periodically. I clean the flame sensor and the unit works fine for a while, but soon the same thing happens again. He also began to smoke heavily. Maybe the problem is that the chimney is short, and it needs to be lengthened?

_____________________________________________________________

Errors of Nike Star, Eolo Star/Mini, Mythos boilers. Malfunctions of boilers with the possibility of automatic unlocking.

My boiler systematically raises the temperature to 80 degrees in winter mode. I called the repairman three times. He said that many models have this problem and suggested installing a programmer, but it’s not certain that it will help. Tell me how to solve this problem and will this programmer help?

Models 11.6; 17.4; 23.2; 29.3 kW. Specifications. Control elements of the automation unit. Installation and maintenance. Malfunctions and their elimination.

The AOGV gas boiler was installed and put into operation. Problem with hot water supply. The heat exchanger was washed. Less than a month has passed and the water is not flowing again. We put a filter on the water, but time passed, and again there was no hot water. What kind of breakdown could this be?

Installation and installation. Start-up and adjustment. Malfunctions and ways to eliminate them.

Technical specifications. Installation and connections. Startup and operating procedure. Automatic adjustments.

The boiler Neva Lux 7023 is malfunctioning. It gives error E7 twice a month. But after reboot it still works. Now it gives error E6. It will work for 15 minutes and turn off. What could it be?

Design and automation unit. Ignition order. Malfunctions and repairs.

Tell me, is it possible that due to low gas pressure the Atem Zhytomyr boiler goes out, a click occurs and goes out. What is the problem? Is it possible to temporarily disable automation and how?

We installed a Lemax KSG-12.5 Premium gas boiler. After turning off the main burner, a clicking sound occurs after a couple of minutes, what is the reason? Tell me?

A KS-G gas boiler of 250 sq.m. was installed and connected. m. When ignited, it does not turn off, the temperature rises, if I am not mistaken, automatic Arbat 1. The flame is not regulated - it is too large. What to do?

I installed the Mayak gas boiler and connected it. It works fine. But the reason is this. When it works on unit it squeaks a lot, if you turn the knob 2-7 the squeak disappears. Tell me, what could it be?

We installed and connected a Danko gas boiler with automatic Kare, it works great on the igniter, but as soon as you add power to the burner, it goes out completely, yesterday it went out within 5 minutes, today it works for about 20 minutes and goes out completely. Has anyone encountered this problem?

The gaseko 18 boiler is in operation. When hot water is turned on, the pressure in the system drops after replenishment, the pressure reaches 3 bar. Have to reset. What's wrong, how to fix it?

Water often boils in the boiler, causing it to fail due to overheating. The heat exchanger was recently washed, the system is not clogged. What's the matter?

Rinnai 167 RMF boiler malfunction. Recently I started showing error 14. How can I fix the problem?

The Celtic DS boiler heats up to 45 degrees and sits all day, does not turn off and does not heat the batteries, sometimes it shows error A3. How can I fix this problem?

The hot water pressure in the Mora Top boiler has dropped. What is the reason?

The Seoul gas wall-mounted boiler stopped turning on due to a no-ignition error. How can it be eliminated? What exactly went wrong?

domdz.ru

How to troubleshoot a gas boiler Zhytomyr AOGV

_______________________________________________________________________________

_______________________________________________________________________________

Tell me how you can solve this problem. We put into operation the AOGV Zhitomir 10 boiler, which includes the Eurosit 630 automation. When you start the ignition, the main burner lights up intensely, but after 15-25 seconds it goes out. Trying to start the situation again does not change the situation. What's happened? Initially check the thermocouple and draft sensor. Check the circuit contacts. Carefully disassemble the pilot burner and clean it. Adjust the ignition mechanism to reduce gas pressure. Apparently, the draft has become poor, which means the pilot burner does not have enough air when the main burner device ignites. The fire began to smoke thoroughly and the burner device burned all the time without dying out. The temperature does not rise above the set one, while the torch continues to burn. A lot of burning. The gas service says that there is insufficient draft. How to fix the problem? Most likely, there is a lack of air. Service is required. Disassemble the gas burner mechanism, clean and rinse the burner and jets. The heat exchanger needs to be cleaned from the outside. Tell me why the unit smokes? What should you do to solve this problem? Perhaps there is a weakening of draft in the firebox. We recommend cleaning the chimney duct. What can be done, please tell me, if the parapet boiler Zhitomir M AOGV 7 does not ignite? I hold down the control handle, press the ignition button, then hold it in this position for about 7 minutes, release it, and it goes out. The igniter tube appears to be dirty. In such a situation, you must do a complete maintenance. Another reason is oxidation of the clamps on the traction sensor. It is necessary to disconnect the terminals and clean them from oxidation. The AOGV 12 boiler with Eurosit 630 automation has problems. If you press the ignition button, gas does not flow to the gas burner. What could be the reasons? When this key is pressed, fuel flows only into the ignition device, it does not enter the main burner. We connected the same unit to the system. I don't like the cycle of transition from the ignition mechanism to the main gas burner device. It turns out two claps. It should be? It is probably necessary to adjust the automation based on gas pressure. A similar unit with Eurosit 630 gas automatic equipment has been installed and connected; it turns off when it heats up to about seventy degrees. Explain to me how to fix the problem? Most likely, the traction sensor is turned on. There is a need to check the chimney. This unit was put into operation. Yesterday it experienced a heating failure at fifty degrees, while the torch continues to burn intensely. What's happened? Most likely, the gas supply pipe from the automation on the gas burner device, as well as the burner nozzle, is clogged with dirt. At home there is a gas boiler AOGV Atem Zhitomir, which includes Eurosit 630 automation. Three days ago, a problem was discovered with it. It goes out when a wind blows onto the pilot burner. I changed the thermocouple a month ago, but nothing helped. How to fix it? When the main burner device starts working, this creates a decrease in the fuel input to the igniter, which means the automation unit is activated. You need to add fuel to the pilot burner. This occurs mainly due to a drop in pressure in the system. In some cases, there may be a decrease in draft in the chimney if it is installed incorrectly. Can you tell us what the problem is if this model stops for us, especially when there is strong wind and bad weather outside. How should I fix the problem? At the moment the ignition device is started, the solenoid valve must operate within 25 seconds. When the ignition wick goes out, the solenoid valve turns off within ten seconds and you will hear a clicking sound. Quite a long time ago I installed a Zhitomir AOGV 15 boiler in a private house. The building is modest, with an area of ​​approximately 30 m2. As you can see, the volume is small, and the heating of the coolant does not exceed 60 degrees. There are two radiators in the room with 10 sections each. I can’t figure out how to raise the heating temperature? To eliminate the problem, you need to install a circulation pump. Often a decrease in pressure in the gas line may occur. Why does a gas boiler often overheat during operation? A significant factor is the lack of circulation in the heating circuit. There may also be a clogged filter or a large accumulation of air in the heating system. We got into trouble. If you close the cold water valve and start opening hot water, water comes out of the heating system. Why does this happen? The heating circuit make-up valve is probably not functioning correctly. It allows water to move in both directions. If there is water pressure in the system, then leakage in the other direction should not occur. Why does the unit make noise, gurgle, and occasionally howl and even clap? The liquid in the system is thoroughly filled with oxygen. During the heating process, air evaporates, which causes noise. If the unit settings are incorrect, the gas valve or bypass valve howls. Popping noises during startup indicate a malfunction of the ignition mechanism. At the end of 2014, repairmen connected the gas boiler Zhitomir M AOGV. About a few months later, this is what happened. I'm trying to adjust the temperature, but it doesn't hold it. I would like to know what could be? It seems that there is a malfunction with the automation, and when the temperature rises by 60 degrees, the injectors turn off. It is necessary to configure the automation for correct operation. Another reason may be that you have chosen an unmatched unit power relative to the areas that need to be heated. I installed this unit myself in the middle of this year. It runs on liquefied gas. Almost nine cubic meters were spent in a few months. At this time, there is too much carbon deposits inside the device, and the burner has also begun to smoke. What is the reason for this phenomenon? Excess soot in the combustion chamber means that the burner is not adjusted, and as a result, gas fuel may not burn completely. There may also be a low-quality composition of the gas mixture. To prevent the burner from smoking, it is recommended to clean it promptly using water. The same device is in use. During the start, the gas burner ignites and immediately goes out. Apparently the igniter is not working properly. How to fix such a breakdown? Check if you can hear a sound when the ignition mechanism sparks if the ignition wire is disconnected. If there is no sound, the ignition transformer must be replaced. If there is sound, replace the ignition electrode or pilot burner. Recently a problem appeared with the parapet boiler AOGV Zhitomir 7. Water is leaking from it. It worked properly for a total of 2 weeks. Perhaps someone will tell you why the water is dripping? Dripping may occur due to excessive pressure in the heating system. It is also likely that the walls of the heat exchange device have collapsed. Water hammer can also be a source of leakage in the boiler. We are going to connect this device to the heating system. Please inform us what is the declared natural/liquefied gas supply pressure for such devices? In this type of boiler devices, the standard gas supply pressure (natural/liquefied) is 150/300 Pa. The same device was put into operation. The day before yesterday I noticed a malfunction in its operation. It starts to function, but does not heat in heating mode. What is the problem? Perhaps air is accumulating inside the batteries or there is a lot of scale in the heat exchanger. Try rinsing it. We use this device in our home. Until this evening, he performed the functions without question. At the moment he has a problem. The unit is rapidly overheating. How can I fix this problem? It is possible that scale has become clogged, causing the flow to become clogged. You just need to clean the device. Recently a problem with the boiler was discovered. The unit operated for only 3 months. Then suddenly, unexpectedly, it stopped raising the desired temperature. Perhaps someone can tell what's going on? Your system has less than required gas pressure. You need to check the gas valve. Most likely, there is too much lubricant inside. The extra one needs to be removed. Explain how you can pump up the expansion tank? The expander tank is pumped up with a conventional automobile pump to the pressure required according to the passport. Basically the average volume is 1-1.5 bar. Before pumping up the expander, the liquid should be drained from the boiler. This is done through the drain fitting or through the water tap, turning off the hot water supply. The AOGV Zhitomir 3 boiler does not start. As long as you keep the power button pressed, the burner operates. As soon as you do not fix the key, the unit goes out. Explain the cause of the problem? The thermocouple or gas valve may have failed. There is also a decrease in gas pressure at the inlet pipes. Sometimes the electronic board voltage is too low. Tell me, what kind of service work is regulated to carry out in order to change methane to propane? First you need to replace the main burner nozzles. Reconfigure the modulator supply voltage. Finally, adjust the minimum and maximum pressure parameters. How does a heating system safety valve work? Such a component, which is adjusted to the required pressure, protects the heating system. It is not permitted to operate the safety valve to empty the system. The pressure in the heating system periodically increases. We reduce the pressure of the expansion tank to the level of 2.1-2.3 atm. Can water from the heating system leak from the hot water pipes? The rise in pressure of the heating system is formed by 2 main reasons. The pressure for the expansion tank is not set. The make-up tap is leaking. A problem has occurred. The start is very difficult. The pilot burner lights, but the main burner does not fire. Can't find out what the reason is? Apparently, there is a breakdown of the ignition mechanism components. We recommend performing a technical inspection of the device and cleaning the ignition mechanism. Can anyone please help me fix the problem with the chimney duct? Soon after three days, a return draft appeared, and smoke began to immediately enter the room. I made the chimney myself. It is a steel pipe. It looks like there was an error in the calculations. The main factor may be an incorrectly manufactured chimney pipe structure. The pipe may become contaminated with combustion products, which sharply reduces its efficiency. In addition, it is advisable to check the ventilation in residential areas.

_______________________________________________________________________________

_______________________________________________________________________________

  • Gas boilers
  • Electric boilers
  • Boiler error codes
  • Troubleshooting boilers
  • Gas water heaters
  • Malfunctions and repairs of geysers
  • Water heaters
  • Troubleshooting water heaters
  • Repair of indirect heating boilers
  • Troubleshooting electric convectors

_______________________________________________________________________________

  • BAXI ECO FOUR

Heating system control. Installation. Connection. Transfer to another type of gas. Adjustment devices and protection devices.

  • BAXI LUNA

Peculiarities. Installation and assembly. Automation components.

  • BAXI MAIN FOUR

Technical specifications. Installation. Adjustment and checking. Maintenance.

  • BAXI SLIM

Adjustment and protection. Installation and assembly. Pressure setting. Maintenance.

_______________________________________________________________________________

_______________________________________________________________________________

  • BAKSI - REPAIR

After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again. It turned on once, but it gives error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me, what could it be?

  • BAXI - OPERATION

In operation, the Baxi main four 240 boiler shuts down with error E35 (stray flame). Tell me what to do? First season in operation.

  • BAXI - SETTINGS

We installed and connected the Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW device?

  • BOSCH - REPAIR

Bosch 6000 24 kW boiler, single-circuit with built-in three-way valve. The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler?

  • BOSCH - ADJUSTMENTS

If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3?

  • ARDERIA - REPAIR

We installed an Arderia esr 2.13 ffcd boiler. If my coolant pressure drops slightly by a couple of notches over 2-3 days, could the reason be a faulty three-way valve (there are no leaks from the radiators)?

  • ARDERIA - ADJUSTMENTS

The gas boiler Arderia 2.35 is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power?

_______________________________________________________________________________

  • BUDERUS FLOOR

We installed and connected the Buderus Logano G234-WS-44 kW boiler, automatic Logomatic 4211. Heating is based on cylinders without hot water, and the jets for reduced gas were also replaced. We survived the winter, the cylinders were replaced, all without problems. Then in the spring, when the outside temperature was +16+18, the boiler began to turn off for a long time and when turned on, it began to display a burner error on the screen and the red button light on the front wall came on. We pressed the button, turned the power back on and everything worked. This happened several times, then the boiler was turned off completely for the summer, what could be the problem?

  • BUDERUS WALL

In the single-circuit Buderus 072, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on the 2-circuit one that is used for DHW?

  • VAILLANT - REPAIR

Tell me, for Vaillant wall-mounted gas boilers, are there real/actual differences for the better in the new generation turboTEC plus VU/5-5 compared to /3-5?

  • VAILLANT - ADJUSTMENTS

There is a malfunction in the boiler, the green LED (power) is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board. How to fix? I checked all SMD resistors and transistors, everything is fine.

  • DAEWOO

In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer. I removed the three-way valve, there is no dirt or wear. It seems that the board does not control the three-way valve. How to check?

  • ELECTROLUX

The Electrolux Basic Xi ​​wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after 7-8 seconds. And after 3 attempts it gave error E1. How can I fix it?

  • KOREA STAR

Koreastar boiler malfunction. The heating works perfectly, the hot water comes intermittently, when you turn on the hot water tap, cold water comes out first, then boiling water. After a few seconds it’s cool, then boiling water again. What could be the problem?

  • FERROLI

Malfunction of the Ferroli Domiproject 24 boiler - I set it to 60-70 degrees, it switches to minimum combustion, does not turn on, does not turn off. Restart is unstable. No pattern emerges. What to do?

  • JUNKERS

In operation, a Junkers euroline gas boiler, when hot water is turned on, gas ignites, then goes out, and so on several times. If you turn it on while the heating is running, the water heating starts immediately. Tell me, please, what could be the problem?

  • NAVIEN

Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.3. It is not possible to adjust the fan run-on. I set it to 30 seconds, but still 2 minutes. spins.

  • OASIS

Malfunction of the Oasis ZRT18 boiler. The unit starts, the gas lights up, then goes out. It lights up again and then goes out (this happens three times). Then it lights up and works fine. It doesn't give any error. What is the reason?

  • SAUNIER DUVAL

Malfunction of the Senor Duval gas boiler - the water pressure sensor shows 0.0, the indicator flashes red, the hot water does not heat up, but the water pressure in the apartment is good. How to fix the problem?

  • VIESSMANN

Where should a condensate trap be installed in a coaxial chimney? The boiler wh1d with a closed combustion chamber is located at a distance of 1 m from the wall.

  • WESTEN

Problem starting the Westen Pulsar D boiler. Piezo ignition works, but there is no flame, error E01 after a crackling sound. I moved the fork around.

  • BERETTA

The Novella floor-standing gas boiler is blocked - the green lights on the panel are on and nothing else happens. How to fix?

  • ARISTON

An Ariston gas wall-mounted boiler has been installed and connected, which does not hold pressure at all: while cooling the heated water, the pressure drops to zero, although water is regularly filled. What about the pressure?

  • SIME

Metropolis dgt 25 bf boiler malfunction. The hot water supply has stopped working, the heating is working, it does not display an error. What do you advise?

  • SOLLY

Please tell me how to solve the problem. The Solly Standard boiler, whenever you try to turn it on or hot water, displays a GS error.

  • WOLF

Wolf boiler in operation. Lately it has begun to behave strangely: during the pause between starts, it turns on the burner for one second five times, and 70 degrees appears on the display. Where to look for a problem?

  • ACV

ACV Wester Line works very unstable: it often crashes, makes a characteristic knock and stalls when starting, but at times everything is fine. The unit is almost new, what's wrong with it?

  • DEMRAD

In the gas boiler Demrad, the gas supply to the burner stopped. The piezo element clicks, but there is no ignition. There is nothing wrong with the gas stove, there is gas. What is the reason?

  • KITURAMI

The Kiturami world boiler is malfunctioning and stops periodically. I clean the flame sensor and the unit works fine for a while, but soon the same thing happens again. He also began to smoke heavily. Maybe the problem is that the chimney is short, and it needs to be lengthened?

_____________________________________________________________

  • IMMERGAZ - ERRORS

Errors of Nike Star, Eolo Star/Mini, Mythos boilers. Malfunctions of boilers with the possibility of automatic unlocking.

  • IMMERGAZ - REPAIR

My boiler systematically raises the temperature to 80 degrees in winter mode. I called the repairman three times. He said that many models have this problem and suggested installing a programmer, but it’s not certain that it will help. Tell me how to solve this problem and will this programmer help?

  • AOGV

Models 11.6; 17.4; 23.2; 29.3 kW. Specifications. Control elements of the automation unit. Installation and maintenance. Malfunctions and their elimination.

  • AOGV - REPAIR

The AOGV gas boiler was installed and put into operation. Problem with hot water supply. The heat exchanger was washed. Less than a month has passed and the water is not flowing again. We put a filter on the water, but time passed, and again there was no hot water. What kind of breakdown could this be?

  • AGV

Installation and installation. Start-up and adjustment. Malfunctions and ways to eliminate them.

  • AKGV

Technical specifications. Installation and connections. Startup and operating procedure. Automatic adjustments.

  • NEVA LUX

The boiler Neva Lux 7023 is malfunctioning. It gives error E7 twice a month. But after reboot it still works. Now it gives error E6. It will work for 15 minutes and turn off. What could it be?

  • ROSS

Design and automation unit. Ignition order. Malfunctions and repairs.

  • ATEM ZHYTOMYR

Tell me, is it possible that due to low gas pressure the Atem Zhytomyr boiler goes out, a click occurs and goes out. What is the problem? Is it possible to temporarily disable automation and how?

  • LEMAX

We installed a Lemax KSG-12.5 Premium gas boiler. After turning off the main burner, a clicking sound occurs after a couple of minutes, what is the reason? Tell me?

  • KEBER

A KS-G gas boiler of 250 sq.m. was installed and connected. m. When ignited, it does not turn off, the temperature rises, if I am not mistaken, automatic Arbat 1. The flame is not regulated - it is too large. What to do?

  • LIGHTHOUSE

I installed the Mayak gas boiler and connected it. It works fine. But the reason is this. When it works on unit it squeaks a lot, if you turn the knob 2-7 the squeak disappears. Tell me, what could it be?

  • DANKO

We installed and connected a Danko gas boiler with automatic Kare, it works great on the igniter, but as soon as you add power to the burner, it goes out completely, yesterday it went out within 5 minutes, today it works for about 20 minutes and goes out completely. Has anyone encountered this problem?

  • GAZLUX

The gaseko 18 boiler is in operation. When hot water is turned on, the pressure in the system drops after replenishment, the pressure reaches 3 bar. Have to reset. What's wrong, how to fix it?

  • NOVA FLORIDA

Water often boils in the boiler, causing it to fail due to overheating. The heat exchanger was recently washed, the system is not clogged. What's the matter?

  • RINNAI

Rinnai 167 RMF boiler malfunction. Recently I started showing error 14. How can I fix the problem?

  • CELTIC

The Celtic DS boiler heats up to 45 degrees and sits all day, does not turn off and does not heat the batteries, sometimes it shows error A3. How can I fix this problem?

  • MORA

The hot water pressure in the Mora Top boiler has dropped. What is the reason?

  • MASTER GAS SEOUL

The Seoul gas wall-mounted boiler stopped turning on due to a no-ignition error. How can it be eliminated? What exactly went wrong?

Gas boiler won't ignite or won't turn on?

Almost every modern house is heated by gas, which involves the use of a gas boiler. This is the type of equipment that must work without failures and be in good working order. But any equipment tends to break down and fail, which, as a rule, happens in the most severe cold weather. Why the gas boiler does not turn on, Kulibins are trying to find out on their own, which is categorically not recommended.

Repair of gas equipment should be carried out by qualified specialists trained in working with gas hazardous equipment. Only they can find the reason why the gas boiler does not light up and ensure one hundred percent safety of the residents of the house.

What are the reasons for the extinguishing of a gas boiler?

The gas boiler does not turn on due to the influence of external factors and breakdown of the equipment itself.

External factors:

  • poor chimney draft
  • low pressure in the line
  • malfunction of the gas meter throughput
  • lack of electricity
  • ignoring gas boiler maintenance, leading to filter clogging
  • drafts in living space
  • small amount of supply air
  • breakdown in the heating system

Problems with gas equipment

Modern equipment is designed in such a way that at the slightest failure, the automatic devices are activated, the operation of the boiler is suspended and the gas boiler does not turn on. Automation may fail in the following cases:

  1. As a result of low pressure in the line.
  2. Poor draft in the chimney.
  3. External influence on the burner

The more complex the design of a gas boiler and the more functions it contains, the higher the percentage of parts failure, as a result of which the automation blocks its operation and the gas boiler does not ignite.

The most popular malfunctions why a gas boiler does not turn on are:

  • Increased burner ignition time, which is caused by clogged sensor photocell. To eliminate the problem when the gas boiler does not ignite, it is necessary to clean the sensor and re-ignite.
  • Incorrect operation of the draft sensor, which results in blocking the flow of gas to the burner and nozzles. Repair involves cleaning the sensor. Practice shows that in most cases this part must be replaced with a new one.
  • Failure of the thermocouple, resulting in failure of the burner to operate when the adjustable wheel is down during ignition. In this case, the part also needs to be completely replaced.
  • Coolant pressure sensor malfunction. In emergency situations when the gas boiler does not ignite, it is possible to connect the contacts directly. Repair involves replacing a part.
  • Display failure. This indicates that the controller fuse has broken down, the gas boiler does not turn on, and it requires replacement. Sometimes such a malfunction occurs as a result of an incorrectly set phase. To eliminate this malfunction, pull out the plug and insert it with the reverse side, having first turned it over.

As you can see, there are quite a lot of malfunctions. And only a specialist can find the reason why a gas boiler does not light up.

www.2-004-004.ru

Basic problems, maintenance and settings of gas boilers AOGV Zhytomyr

For 2 days now there has been a reverse draft, in which the smoke passes directly into the kitchen. I did the chimney myself. It is made of steel pipe. There are probably some flaws in the calculations. The main reason is an incorrectly executed chimney configuration.

There may be soot deposits on the pipe walls, which noticeably reduces its functionality. In addition, it is necessary to control the exhaust openings in the room. Heating system control. Transfer to another type of gas. Adjustment devices and protection devices. After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again.

It turned on once, but it gives the error E10 water pressure, although the pressure in the system is 1. Tell me, what could be wrong? In operation, the Baxi main four boiler turns off with error E35 stray flame. Tell me what to do? First season in operation. We installed and connected the Baxi Fourtech 24 F boiler.

Questions about the operation and repair of Alphatherm gas boilers. Recommendations for operation, repair and settings of Biasi boilers. Recommendations for setting up and operating the Resanta convector. I ask for help to fix this problem. After ignition, the main burner device burns brightly, but goes out after seconds.

What cold water pressure is allowed at the inlet to the DHW device? Bosch boiler 24 kW, single-circuit with built-in three-way valve. The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler?

If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3? Installed an Arderia esr 2 boiler.

If my coolant pressure drops slightly by a couple of notches over the course of a day, could the reason be a faulty three-way valve? Are there no leaks from the radiators? The Arderia 2 gas boiler is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power? Heating is based on cylinders without hot water, and the jets for reduced gas have also been replaced. We survived the winter, the cylinders were replaced, all without problems. We pressed the button, turned the power back on and everything worked.

Create an account or log in to comment

This happened several times, then the boiler was turned off completely for the summer, what could be the problem? In a single-circuit Buderus, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on a 2-circuit one that is used for DHW? There is a malfunction in the boiler, the green power LED is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board.

How to fix? I checked all SMD resistors and transistors, everything is fine. In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer.

I removed the three-way valve, there is no dirt or wear. It seems that the board does not control the three-way valve. How to check? The Electrolux Basic Xi ​​wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after seconds.

And after 3 attempts it gave error E1. How can I fix it?

how to turn on, light and ignite the boiler, first start-up in photos and videos

Contents:
1. How to start a gas boiler: preparation 2. Rules for filling the system with water before turning on the gas boiler 3. Removing air pockets before lighting the gas boiler 4. Useful tips

When arranging a heating structure, many homeowners prefer installing double-circuit gas boilers. These heating units, when installed in modern models, are reliable, they are economical and allow you to provide hot water supply in the house, but it is important to know how to start a gas boiler correctly the first time.

In order for the device to work for a long time and without repair, you need to properly organize the first start-up of the gas boiler, during which the system is filled with water and the air trapped in them is removed from the pump and heating batteries. To facilitate this process, special devices are used for radiators - Mayevsky taps. They should be unscrewed until water comes out of them.

To ensure that no air remains in the pump, first remove the front panel of the unit and make the necessary adjustments. Air pockets are quickly removed, and the equipment automatically starts working.

How to start a gas boiler: preparation

There are simple instructions explaining how to start the gas boiler shown in the photo.
The initial start-up is carried out when the installation and wiring of all elements of the heating equipment is completed, and the correctness of the work has been verified by the relevant authorities. The location of the heating unit must be selected in accordance with safety standards and regulations that prevent fires. The boiler must be located at a certain distance from the wall, which depends on the manufacturer's recommendations. By the way, for some models of gas appliances this requirement is not relevant. You should also make sure that there are no flammable materials or objects nearby.

In addition, it is prohibited to place boilers near windows, as their operation will be disrupted. The even position of the device body is of no small importance - even minor distortions are unacceptable.

After installation is completed, they begin to connect the equipment to a source of cold water: remove the plugs from the pipes, and place a filter with a ball valve at the inlet. Such a device protects the heating structure from all kinds of contaminants that cause damage. Ball valves must be installed on all pipes used for piping.


When solving the problem of how to start a gas boiler, special attention should be paid to the supply of pipes from the gas main. They do not carry out this installation work themselves, but invite specialists from the relevant services who are involved in connecting, sealing and, if necessary, installing a gas meter.

Before you turn on the gas boiler, you should lay a separate power line specifically for the heating unit. The equipment must be equipped with an electrical cable and plug, and an outlet must be installed next to the device, separating it from the others.

After this, the boiler is connected to the chimney pipe, in which the draft and its performance are checked.
She must go outside. The installation work to install the chimney depends on the type of heating device. When preparing for startup, the boiler is disconnected from the power supply to fill it and the heating system with cold water. Then they check for leaks, turn the thermostat to the maximum value so that the operating mode switch lights up in automatic mode.

Rules for filling the system with water before turning on the gas boiler

Before lighting a gas boiler and turning on the heating system, it is first filled with cold coolant, which, after heating, will circulate through the pipes and radiators. During the first launch, everything is carefully checked so that further operation is uninterrupted and the equipment does not require repairs.

The unit body has a special tap located near the pipe to supply coolant to the system. During the filling process, the pressure in the system is monitored thanks to the presence of sensors and pressure gauges. In modern boilers they are already installed and there is no need to purchase them additionally. When the device is filled with water, the mark on the sensor rises. When it reaches the 1.5-2 atmosphere mark, the water supply is shut off and thus completing the filling.


These pressure parameters can be changed as they depend on the manufacturer's requirements for the operating pressure in the heating system. But filling with cold water does not end there, since replenishment will be required after the structure is freed from air pockets.

Removing air pockets before lighting a gas boiler

Before lighting a gas boiler, you need to fill the heating structure with liquid cold coolant.
But just filling with water is not enough. It will either not work, or the degree of heating of the room will be insufficient. A full first start is impossible without releasing the air accumulated in the system. Often modern gas boilers have a special system that automatically releases air when filling. But often its effectiveness is insufficient: you will still need to manually reset the air locks. Only after this can you start. It is necessary to remove air pockets before turning on the gas boiler not only from the heating unit, circulation pump, but also from all heating radiators. The process should begin with batteries - for this, as mentioned above, they will be equipped with Mayevsky cranes. They are opened by placing a container underneath. First, a slight whistle will be heard, indicating that air is gradually leaving the system. After removing the plugs, water begins to flow. Then the taps are closed. A similar procedure should be done with each of the radiators.

Maintenance of gas heating boiler Atem (Zhytomyr) / Natural gas boiler

No critical contamination was found during cleaning, but it is clear that dirt accumulates throughout the year. The need for such a procedure is obvious.

From 1 to 5 it will work and the gas supply will be turned off. It works fine on 6 and 7. The second season has worked, the circulation pump is installed.

Questions about the operation and repair of Alphatherm gas boilers. Recommendations for operation, repair and settings of Biasi boilers. Recommendations for setting up and operating the Resanta convector. Tell me how you can sort this issue out. After ignition, the main burner begins to burn intensely, but goes out after a second.

It even happened that the igniter did not light up, cleaned the terminals, worked normally for about a day and began to turn off again. In principle, it’s already spring, and you don’t want to call an unfamiliar gas worker. Yes, maybe I can figure it out on my own. Can anyone tell me what the problem might be and its solution? The igniter flame - the root third is bluish, the middle and top are yellow, fluctuates quite strongly.

Igniter and filter

In general, in the fall there was a strange symptom: if you turn on the igniter and immediately turn on the burner, the gas supply turns off after a minute or two. And if the igniter burns for five minutes, the gas supply does not turn off. We had a similar situation.

During assembly, the thermal breaker was not completely screwed into the magnetic valve. Apparently the contact between them was not initially the strongest, and over the two seasons of work the contact worsened. And apparently, there was not enough contact, but there was enough. We tightened it a little more and everything became normal. I had the following problem: the Zhitomir-M parapet gas boiler, installed last year, began to go out. The most interesting thing is that it goes out in position 2 and 1 in position 3 lights up without problems.

This happened just yesterday, before that everything was normal. The house is heated by a 15 kW Zhitomir-3 gas boiler. Atmospheric gas burner with igniter. Is it possible to install an electric ignition so that the device ignites without an igniter? My igniter goes out and, interestingly, at a certain wind direction. I do not know what to do. If the pilot burner goes out while the main burner is running, try reducing the gas pressure to the main burner.

When starting the boiler, while gas is supplied to the igniter, the following happens: I press the gas supply “key”, gas flows to the igniter, I release the gas “key” - it still “goes”. The metal plate does not heat up as before; gas has to be supplied to the main burner immediately. This phenomenon began gradually, from year to year it was necessary to hold down the “key” less and less, now it is not necessary at all. And on top of that, it began to fade up to 5 times a day. It used to happen that it would go out once a season.

I checked the traction - the traction is excellent. Can you see something wrong with the equipment? I advise you to switch to automatic Sit. Atem boiler malfunction. Minisit automation installed. Now when you press the ignition button, gas flows and ignites from the button.

According to the instructions, you need to hold it for 10 seconds, but it turns off. The traction is normal, I replaced it with a new one. 3 meters higher than the roof, not blown by the wind. The thermocouple is ok, I checked it with a tester, when it heats up the current reaches mVolt. I also cleaned the contacts. What could be the reason? How does the operation of the safety magnetic valve installed in the automation depend on the presence of air in the expansion tank? Last year I bleed the expansion tank by mistake and it worked until the end of the season.

This year I worked for a month. On the advice of specialists, I decided to pump it with air and drained all the water from the system the day before yesterday and at the same time change the exhaust pipe. It was not possible to pump in air, there was a problem with the pump, and the pipe was changed. And from then on the problems began. To light the igniter, neither draft nor water is needed in the system. If the thermocouple is ok, then look for a bad connection somewhere or an open in the draft sensor.

Can be short-circuited temporarily. And then - more, in the automation itself, for example, EHR. The gas parapet floor-standing boiler Zhitomir 20 with Eurosit Italy automation went out. I light it with a piezo ignition, the wick burns as long as I hold the button, as soon as I release the button it goes out. We unscrew the nut going into the valve, pull out the copper tube tail of the thermocouple, not the gas one!

Then, using the tester, in the ohm-kilo-ohm resistance measurement mode, we measure between the center and the tube. If the instrument readings do not change, then the thermocouple has burned out; if they change, you can check further. We light the wick, set the tester to millivolt mode, and after 10 seconds we measure the voltage. About 20 mV is normal, more is better. If it is less, then perhaps the flame is barely reaching the sensor, then unscrew the igniter. That's it with a thermocouple. Now the valve. Resistance tester, one contact on the metal of the valve, the second in the center of the hole, from where the tail of the thermocouple was pulled out, without touching the edges of the thread with the probe.

If it's about 0 ohm, then it's normal. If you want, then look further - the battery with one pole, no matter the metal, the second in the center of the valve with insulated wiring. We press the button, light it and immediately release it, no need to wait. If it continues to light, the valve is normal. If the contacts have been oxidized, they will be cleaned after unscrewing and tightening.

If there is a draft sensor in the chimney area, with two wires, we can close its contacts with a paper clip in place, or insert one into the other. A double-circuit gas boiler Atem Zhytomyr 3 was installed.

This year I made myself a closed heating system using polypropylene pipes with aluminum radiators, it worked fine for two months, and then suddenly the pressure in the system began to drop.

I checked everything, there are no leaks anywhere, I tried pumping water into the system and pumping pressure into the expansion tank, it helps, but for a while, after about a day, the pressure gradually begins to drop. Tell me what to do? The pipes are all open, that is, visible and easy to access. My highest point is the protection group, which is located immediately behind the boiler; the pressure was previously maintained at 2 atm.

I checked the expansion diaphragm - normal.

Your unit is sectional, made up of separate sections, I would start by checking it. There is no need to fill with air with water - it expands much more when the temperature rises; look at the maximum pressure in the passport and wait for a day. You can then check the entire system in the same way if necessary.

But these are things for the month of May.

We bought a gas boiler Atem Zhitomir-3; there were no problems when we first started it, since it was in April, it was turned off for a day, and when we started it again, fire came out of all the cracks. They turned it off, tried to start it again, but gas did not flow into the boiler. You need to look at the chimney. But the boiler did not turn on again due to the activation of the draft sensor.

Now you can lower the pressure in the system to 1 Atm. In your case, the pressure in the system is only needed to reliably close the automatic air vent. Pay attention to the membrane tank. Personally, I had a case with a pumping station: I bought a 50 liter hydraulic accumulator for installation, immediately after purchase I checked the air pressure of 1.2 Atm, installed it, since it was supposed to work with a water pressure of 6 Atm. After 2 weeks they called - “the pump twitches”, that is, it constantly turns on and off, pumped up the air - after 2 weeks the same thing, after a very long search they found 2 microscopic pores in the weld seam of the air cavity of the tank.

We brewed it with argon - everything was fine for 2 years. We installed the Atem boiler with Eurosit automation. Connected it, pressurized it, everything was fine. We lit the igniter according to the instructions, it burns normally.

The boiler ATEM Zhitomir-3 KS-G-010SN Eurosit 630 is switched off

We put into operation a unit of the same model equipped with Eurosit automation, which turns off when the temperature rises to approximately 65 degrees. Tell me, how can I get rid of this problem? A device of the same model is installed in the house.

At the beginning of the week, the heating stopped at forty-five degrees, but the flame invariably burns. What could be the reasons? Apparently, the gas supply tube from the automation unit on the gas burner device, and also the burner nozzle, were clogged. About three days ago he had a breakdown.

The appliance goes out if wind blows on the pilot burner.

I recently replaced the thermocouple, but there is no change. How to fix it? When the main burner turns on, this serves to reduce the gas supply to the ignition device, so the automation unit should turn on. You should increase the gas supply to the igniter.

This happens regularly due to low pressure in the system. In some cases, there may be a decrease in draft in the chimney if it is not designed correctly. Explain to me why this model sometimes stops working, especially when there is strong wind and rainy weather outside. How should the problem be resolved? At the moment the igniter is started, the EMC must operate for 25 seconds.

When the igniter goes out, the EMC function will be interrupted in a cycle of ten seconds, at which point a click will be heard. About 5 years ago, a double-circuit boiler Atem Zhitomir 3 was installed in a private house. The house is modest, the space is about 40 sq. m. You might think, 0 although the water cannot heat above fifty degrees. The house has 2 batteries of twelve sections each. I can’t figure out how to increase the heating temperature? Installing a circulation pump can save you from the problem. The pressure in the gas line may periodically decrease.

The main factor is that circulation in the heating circuit has disappeared. It is also possible that the filters are dirty or there is an excess of air in the heating system. I have a problem. When you close the cold water tap and turn on the hot water supply, all the water leaves the heating circuit. Explain why this is so? Most likely, your heating system feed tap is faulty.

It allows water to flow in both directions. If there is fluid pressure in the system, then backflow cannot occur. The water in the system is significantly filled with oxygen. During heating, air bubbles are released, which is why you hear noise.

In this article I would like to share with potential buyers of heating boilers our experience in purchasing and operating this device. It all started with the decision to carry out major renovations in our house.

If the unit is not configured correctly, the gas valve or bypass valve howls. Strong pops during the start process indicate a problem with the ignition system.

We launched the KS-G sn boiler in the middle of this year. Approximately six months later, a failure occurred. I'm trying to set the temperature, but it doesn't register it. I would like to know why the temperature does not hold? Apparently, the automation is damaged, and when the temperature rises by 60 degrees, the injectors turn off. It is recommended to configure the automation for proper execution of functions. Another reason may be that you have chosen an inappropriate power of the device relative to the heating area.

I installed this device in early August. They switched it to liquefied gas. Almost eight m3 were consumed in a few months. Currently, there is a lot of carbon deposits inside the device, and the main burner also smokes. Why is this happening? A large number of soot deposits in the combustion chamber indicates that the burner is poorly adjusted, and as a result, gas fuel is not burned in full. An unsatisfactory type of gas mixture is also likely. To avoid soot from the burner, it is necessary to systematically carry out wet cleaning.

I put this device into operation. During the start, the gas burner lights up and immediately goes out. It seems to me that there is no ignition spark. How can I fix this problem? It is necessary to check whether a sound appears when an ignition spark occurs when the cable is removed for ignition. If there is no sound, it is recommended to change the ignition transformer. If there is sound, replace the ignition electrode or gas burner device.

Quite recently, a problem was discovered with the gas boiler Zhitomir 3. Water began to drip from it. The unit operated for only 2 months. Tell me why the water flows?

Apparently it drips due to high pressure in the system. There may be destruction of the walls of the heat exchanger. Water hammer is also a cause of leaks in boilers.

We intend to implement the connection of this device in the apartment. I installed this device. Recently I noticed a problem with its operation. The boiler starts, but the heating does not heat. What can happen? Most likely, there is an accumulation of air inside the radiators or there is scale in the heat exchanger. It needs to be washed. I installed and connected this unit in the apartment. Until this morning he acted properly. Now he has a problem. It overheats many times. How to repair such an accident?

Probably, there was a blockage with scale, so the duct was clogged. You must clean the device. Just yesterday we discovered a problem with the boiler. I was at work for a total of 2 weeks. Then it suddenly stopped raising the set temperature. Tell me why this happened?

The system may have lower gas pressure than recommended. The gas valve needs to be inspected. It looks like there is too much lubricant inside. Try clearing away the excess. The expansion tank can be pumped up with any car pump to the pressure required according to the passport. Usually the volume is equal to Before pumping up the expander, it is imperative to drain the coolant from the boiler. This is done through a drain fitting or through a water tap, shutting off the hot water supply.

The floor-standing boiler Zhitomir 3 KS-G sn cannot start. As long as you keep the start button pressed, the burner works. If you release the button, the device goes out. What is the cause of the malfunction? It looks like the thermocouple is defective or the gas valve is broken. There is also a decrease in gas pressure in the inlet pipeline. Sometimes there is a lack of voltage on the control board. Please tell us what repair work needs to be done to change the type of gas?

This valve, adjusted to the operating pressure, serves the heating system. Do not use the safety valve to drain the system. From time to time the pressure in the heating system increases.

We reduce the pressure in the expansion tank to limit 2. Could it be that the heating circuit water comes from the hot water supply pipes? The rise in pressure in the heating system can be explained by the following main factors.

Incorrect pressure settings for the expansion tank. The fill valve is leaking. There is a problem. Ignition is difficult. The igniter is lit, but there is no flame at the main burner assembly.

Help me figure out what is the reason? Most likely there is a functional malfunction of the ignition mechanism. You need to check the device and clean the ignition device. Can anyone help me troubleshoot my chimney pipe? For 2 days now there has been a reverse draft, in which the smoke passes directly into the kitchen. I did the chimney myself. It is made of steel pipe. There are probably some flaws in the calculations. The main reason is an incorrectly executed chimney configuration.

There may be soot deposits on the pipe walls, which noticeably reduces its functionality. In addition, it is necessary to control the exhaust openings in the room.

Preparing for work

Heating system control. Transfer to another type of gas. Adjustment devices and protection devices. After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again.

It turned on once, but it gives the error E10 water pressure, although the pressure in the system is 1. Tell me, what could be wrong? We installed and connected the Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW device? Bosch boiler 24 kW, single-circuit with built-in three-way valve.

The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler? If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3? We installed an Arderia esr 2 boiler. If my coolant pressure drops a little over the course of a day by a couple of notches, could the reason be a faulty three-way valve? Are there no leaks from the radiators?

The Arderia 2 gas boiler is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power? Heating is based on cylinders without hot water, and the jets for reduced gas have also been replaced. We survived the winter, the cylinders were replaced, all without problems. We pressed the button, turned the power back on and everything worked.

This happened several times, then the boiler was turned off completely for the summer, what could be the problem? In a single-circuit Buderus, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on a 2-circuit one that is used for DHW? There is a malfunction in the boiler, the green power LED is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board. How to fix?

I checked all SMD resistors and transistors, everything is fine.

In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer. I removed the three-way valve, there is no dirt or wear.

It seems that the board does not control the three-way valve. How to check? The Electrolux Basic Xi ​​wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after seconds.

And after 3 attempts it gave error E1. How can I fix it? Koreastar boiler malfunction. The heating works perfectly, the hot water comes intermittently, when you turn on the hot water tap, cold water comes out first, then boiling water. After a few seconds it’s cool, then boiling water again.

What could be the problem? The Ferroli Domiproject 24 boiler is malfunctioning - I adjust the degrees, it switches to minimum combustion, does not turn on, does not turn off. Restart is unstable.

No pattern emerges. What to do? In operation, a Junkers euroline gas boiler, when hot water is turned on, gas ignites, then goes out, and so on several times. If you turn it on while the heating is running, the water heating starts immediately. Tell me, please, what could be the problem? Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.

It is not possible to adjust the fan run-on. I set it to 30 seconds. Malfunction of the Oasis ZRT boiler The unit starts, the gas lights up, then goes out. It lights up again and goes out three times, this happens. Then it lights up and works fine. It doesn't give any error. What is the reason? Malfunction of the Senor Duval gas boiler - the water pressure sensor shows 0.

How to fix the problem? Where should a condensate trap be installed in a coaxial chimney? The boiler wh1d with a closed combustion chamber is located at a distance of 1 m from the wall. Problem starting the Westen Pulsar D boiler.

Rating
( 1 rating, average 5 out of 5 )
Did you like the article? Share with friends: