Prices for annual and one-time maintenance of boiler equipment of various types and capacities. Prices for boiler startup work

Home / Tips

Back

Published: 11/17/2019

Reading time: 5 min

0

3604


Do not forget to carry out timely maintenance of gas boilers.

The operation of heating equipment leads to wear of parts, so it may break. Servicing wall-mounted boilers helps to promptly identify the source of the problem and eliminate it.

  • 1 Types of procedure
  • 2 Service goals
  • 3 What is included in the list of services
  • 4 Process execution 4.1 Inspection of critical components
  • 4.2 Cleaning
  • 4.3 Functionality check
  • 5 Briefly about boiler repair
  • 6 Equipment maintenance in emergency conditions
  • The cost of technical (service) maintenance and startup of a wall-mounted boiler.

    Annual and one-time maintenance (TO) of a wall-mounted boiler

    Contract typeCost, rub.
    Maintenance per year Emergency response time hourBoiler power, kW up to 35
    112415 150
    222426 500
    321239 800
    4One-time maintenance10 300
    • Order annual maintenance
    • Order one-time maintenance

    The cost of starting a wall-mounted boiler

    Boiler power, kWup to 35
    Cost, rub.15 500

    Order the launch of a wall-mounted boiler

    Types of procedure

    Services are of the following types:

    ServiceDescription
    TO-1Scheduled inspection is carried out once a year
    TO-2Visits to the master occur twice a year
    TO-3Maintenance consists of 3 inspections and 2 emergency visits per year

    If necessary, emergency repairs are counted as scheduled maintenance. The master arrives on the day the application is submitted.

    Additional calls are paid according to the price list. All materials and spare parts are paid separately.

    The cost of technical (service) maintenance and startup of an atmospheric gas boiler.

    Annual and one-time maintenance (TO) of an atmospheric gas boiler

    Contract typeBoiler power, kW / Cost, rub.
    Maintenance per year Emergency response time hourup to 6061-140141-280
    112417 80020 20029 500
    222431 20035 20051 400
    321246 70052 85077 150
    4One-time maintenance12 95015 28024 039
    • Order annual maintenance
    • Order one-time maintenance
    List of maintenance work performed:
    For annual maintenance
    • Inspection and check of general condition
    • Checking the tightness of the hydraulic circuit
    • Setting the required pressure in the boiler
    • Checking the tightness of a heated boiler
    • Maintenance of the heating expansion tank
    • Checking burner operation
    • Burner cleaning
    • Boiler cleaning
    • Checking the tightness of the gas valve
    • Checking the temperature limiter
    • Checking the traction control system
    • Checking the gas pressure control system
    • Checking the flue gas shut-off valve
    • Checking the ventilation status
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block
    For one-time maintenance
    • Inspection and check of general condition
    • Setting the required pressure in the boiler
    • Maintenance of the heating expansion tank
    • Checking burner operation
    • Burner cleaning
    • Boiler cleaning
    • Checking the tightness of the gas valve
    • Checking the traction control system
    • Checking the gas pressure control system
    • Checking the flue gas shut-off valve
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block

    The cost of starting an atmospheric gas boiler:

    Boiler power, kWup to 6061-140141-280
    Cost, rub.18 80020 00028 000

    Order the launch of an atmospheric gas boiler

    Briefly about boiler repair

    To restore the technical condition of the device, repair work is carried out, replacing damaged elements.

    In addition to diagnostics, the service includes:

    • flushing the heat exchanger;
    • Inspect and clean closed areas of the unit.

    The efficiency of the device deteriorates due to scale that forms in the heat exchanger. It is cleaned every 2-5 years. Flushing the device allows you to get rid of the problem at the initial stage. To carry out major removal of contaminants, it is necessary to remove the casing from the device and disassemble the parts.

    The heat exchanger is disassembled separately; it should be washed with chemicals. When these processes are completed, they begin to assemble the boiler and fill the system with coolant. Chimneys must be checked constantly, either by calling a professional or cleaning them yourself.

    The cost of technical (service) maintenance and startup of a pressurized gas boiler.

    Cost of work for annual and one-time maintenance of a pressurized gas boiler:

    Contract typeBoiler power, kW / Cost, rub.
    Maintenance per year Emergency response time hourup to 6061-100101-230
    112418 65024 15033 500
    222432 60042 20058 500
    321248 95063 30087 850
    4One-time maintenance13 80015 77024 620

    If the boiler is equipped with a combination burner, the contract amount increases by 25%

    • Order annual maintenance
    • Order one-time maintenance
    List of maintenance work performed:
    For annual maintenance
    • Inspection and check of general condition
    • Checking the tightness of the hydraulic circuit
    • Setting the required pressure in the boiler
    • Checking the tightness of a heated boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking the temperature limiter
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning the filter
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking the tightness of fittings
    • Startup check
    • Checking the air sensor
    • Checking the gas pressure sensor
    • Adjusting the combustion process
    • Checking the ventilation status
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block
    For one-time maintenance
    • Inspection and check of general condition
    • Setting the required pressure in the boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning the filter
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking the tightness of fittings
    • Startup check
    • Checking the air sensor
    • Checking the gas pressure sensor
    • Adjusting the combustion process
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block

    The cost of starting a pressurized gas boiler:

    Boiler power, kWup to 6061-100101-230
    Cost, rub.19 70021 00029 000

    Order the launch of a pressurized gas boiler

    Order boiler service at

    The group provides maintenance for gas, liquid fuel, solid fuel, electric wall-mounted and floor-mounted boilers in Kaluga and the region. We work comprehensively, carry out major maintenance and, if necessary, repair equipment at the owner’s site.

    By contacting Profteplo, you get many advantages:

    • high quality, confirmed by licenses and certificates;
    • the technician will arrive on the same day;
    • compliance with current service technologies;
    • only our own qualified employees with permits and licenses for hazardous types of work.

    We can carry out both scheduled and unscheduled maintenance. If necessary, we are ready to enter into an agreement for regular service - annually or at other intervals. By contacting the company manager, you will find out what is included in boiler maintenance and how long the work will take in your case. You can also discuss a convenient time for maintenance. We will adapt to your wishes, the master will arrive on site on time and complete all stages of the work at the proper level.

    For more than 14 years, we have been repairing and servicing heating systems of any complexity. We are ready to perform any type of work inexpensively and efficiently for you. To find out more details or apply for a service, contact the manager directly at the number or use the feedback form on the website. We will contact you ourselves. We work seven days a week. All consultations on maintenance and service issues are free.

    The cost of technical (service) maintenance and startup of a forced-air diesel boiler.

    Cost of work for annual and one-time maintenance of a forced-air diesel boiler:

    Contract typeBoiler power, kW / Cost, rub.
    Maintenance per year Emergency response time hourup to 6061-100101-230
    112425 73029 73040 000
    222436 30043 30060 300
    321254 40064 90090 500
    4One-time maintenance20 73024 73035 994
    • Order annual maintenance
    • Order one-time maintenance
    List of maintenance work performed:
    For annual maintenance
    • Inspection and check of general condition
    • Checking the tightness of the hydraulic circuit
    • Setting the required pressure in the boiler
    • Checking the tightness of a heated boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking the temperature limiter
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning/replacing the pump filter
    • Checking and cleaning/replacing the fuel filter
    • Checking and cleaning/replacing the nozzle
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking pump pressure and suction vacuum
    • Checking the tightness of fuel cells
    • Startup check
    • Adjusting the combustion process
    • Checking the ventilation status
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    For one-time maintenance
    • Inspection and check of general condition
    • Setting the required pressure in the boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning/replacing the pump filter
    • Checking and cleaning/replacing the fuel filter
    • Checking and cleaning/replacing the nozzle
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking pump pressure and suction vacuum
    • Checking the tightness of fuel cells
    • Startup check
    • Adjusting the combustion process
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block

    The cost of starting a pressurized diesel boiler:

    Boiler power, kWup to 6061-100101-230
    Cost, rub.21 00023 00030 000

    Order start-up of a forced-air diesel boiler

    About protection systems

    Now let's talk about gas boiler protection systems. Modern models stop working in the event of a power outage and automatically start when power is restored.

    If the gas supply is stopped, the automation will send a signal to close the solenoid valve that controls the flow of fuel into the boiler. But in this case there will be no automatic switching on - you will have to perform a manual restart.

    Wall-mounted gas boiler Electrolux Basic and Hi-Tech series

    And new models are necessarily equipped with energy-saving functions, as well as frost protection. The temperature of the coolant is controlled using special sensors. If it drops to 5 degrees, the boiler will turn on in order to warm up the heating system.

    There is also a special function that turns on the pump once a day in the summer, when heating is not needed. This is done to ensure that the rotor does not jam due to inactivity for an extended period of time.

    Gas boilers are required to be equipped with self-diagnostic systems. They analyze the state of the boiler room components and inform the consumer by displaying error codes on the display. Your wall technician can diagnose approximately 90% of faults using this system. And service specialists, knowing the error code in advance, arrive to carry out repairs, already fully prepared.

    The cost of technical (service) maintenance and startup of a condensing gas boiler.

    Cost of work for annual and one-time maintenance of a condensing gas boiler:

    Contract typeCost, rub.
    Maintenance per year Emergency response time hourBoiler power, kW up to 100
    112416 350
    222428 600
    321242 900
    4One-time maintenance11 500

    If the boiler is equipped with a combination burner, the contract amount increases by 25%

    • Order annual maintenance
    • Order one-time maintenance
    List of maintenance work performed:
    For annual maintenance
    • Inspection and check of general condition
    • Checking the tightness of the hydraulic circuit
    • Setting the required pressure in the boiler
    • Checking the tightness of a heated boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking the temperature limiter
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning the filter
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking the tightness of fittings
    • Startup check
    • Checking the air sensor
    • Checking the gas pressure sensor
    • Adjusting the combustion process
    • Checking the ventilation status
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block
    For one-time maintenance
    • Inspection and check of general condition
    • Setting the required pressure in the boiler
    • Maintenance of the heating expansion tank
    • Boiler cleaning
    • Checking and cleaning the fan wheel
    • Checking and cleaning air ducts
    • Checking and cleaning the ignition device
    • Checking and cleaning the flame head and retainer washer
    • Checking and cleaning the filter
    • Checking and cleaning the air damper
    • Checking and cleaning the servo drive
    • Checking and cleaning the flame sensor
    • Checking the tightness of fittings
    • Startup check
    • Checking the air sensor
    • Checking the gas pressure sensor
    • Adjusting the combustion process
    • Checking the chimney draft
    • Checking the temperature limiter
    • Checking contacts
    • Checking actuators
    • Setting the temperature mode
    • Checking the sensors
    • Cleaning the block

    The cost of starting a condensing gas boiler:

    Boiler power, kWup to 100
    Cost, rub.19 000

    Order start-up of a condensing boiler

    Process Execution

    In order not to harm the device, you need to know about the repair of its various parts. Routine maintenance includes several stages, which include inspection, cleaning and adjustment. Before starting work, it is necessary to turn off the system and the source of gas supply. Then wait for the disconnected system to cool down.

    Inspection of Important Components

    This step is necessary to diagnose the condition of the equipment. First, the papers are checked and warranty sealing is carried out to determine compliance of the installation with SNiP and rules of use. The boiler requires electricity and gas to operate, so electrical parts are also inspected.

    First, remove the protective casing from the unit and examine the elements and their level of wear one by one.

    The check is carried out to determine:

    • proper operation of emergency machines;
    • presence of pressure in the gas valve;
    • the state of the ignition electrodes, if any;
    • structural integrity;
    • functioning of electronics;
    • serviceability of connections in gas supply channels.

    Afterwards, the expansion tank is controlled and pumped up, protecting the system parts and compensating the pressure that occurs during the expansion of the coolant. Special instruments are used to examine the unit, protective elements and gas communications. The pressure in cold water will average 1.1-1.3 bar. The exact figure depends on the type of equipment. After heating, the value should not be higher than the number indicated in the documents from the boiler.

    Cleaning from contaminants

    First you need to empty the equipment and inspect the gas burner, determining the direction and quality of the flame.

    The following parts must be removed and cleaned one by one:

    1. Support washer. A device that controls the position of the torch in relation to the installed heat exchanger.
    2. An air sensor that regulates the ratio of gas and air mixture.
    3. Flame detector, triggered when the draft decreases.
    4. An electrode responsible for igniting the air-gas mixture.


    To prevent scale from clogging the burner, it must be cleaned in a timely manner using a special brush.

    High temperatures and carbon deposits lead to deformation of metal structures. The burner is considered an important working element of the device, so it should not become clogged with scale. The part is cleaned with special brushes. The burner operates normally when the flame is blue. If its color turns yellow, then contamination must be removed from the element.

    To evaluate the burner settings and check its operation, you need to measure and analyze the exhaust gas in the boiler. Use a soft brush and vacuum cleaner to clean the combustion chamber and all parts of the equipment in contact with the torch. A metal product with hard bristles is not suitable for cleaning injectors. The pipe intended for supplying gas to the burner must be removed, disassembled and purged under pressure.

    The heating system has 2 filter parts located in the hydraulic part and on the cold water tap. Salts are deposited on these filters and need to be washed. During inspection, all problems are eliminated and broken elements are replaced with new ones.

    Functionality check

    The operation of the unit without supervision is carried out using automatic control, which can have different levels of complexity. This technique often suffers from voltage surges. It is recommended to fix problems with electronics immediately and adjust the system in a timely manner.


    The boiler connected to the gas boiler, which supplies the DHW system, must be checked annually.

    The boiler connected to the gas boiler and supplying the DHW equipment is subject to annual inspection. To find out the state of the safety unit and identify vulnerable parts of the device, an accident simulation is necessary. After such a situation, the speed of operation of the alarms, the tightness of the valve and other parts are monitored.

    If the unit does not work correctly, it must be disassembled and the membranes replaced. The inlet part of the gas pipe is also inspected. The entire gas pipeline is studied, especially the pipe connections outside, and the pressure level in it is determined. If there is a need to adjust the fittings, then it is performed. When the paint on the pipes cracks, the product is painted.

    After the work has been done, you need to set the indicators indicated by the manufacturer in the documents, and then check the equipment. The master must fill out papers in which he puts his signature and indicates the date of the next service.

    Troubleshooting

    Let's consider possible malfunctions of wall-mounted gas boilers:

    The cause of boiler malfunction is often the heat exchanger. Made of stainless steel, this important component requires periodic cleaning to remove soot. This is done using a metal brush. The copper heat exchanger is cleaned with a metal sponge for cleaning dishes.

    Charge fan

    Charge fan

    The boost fan is a rather weak link in the heating system, despite the low rotation speed and the fact that its power comes from direct current.

    If the fan rotation speed does not correspond to the specified one, it is necessary to check the operation of the bearings - perhaps the problem lies with them. To do this, it is necessary to disassemble the fan and remove the stator, lubricate the bearings with high-quality carbon-based machine oil designed for operation at high temperatures.

    If the fan housing heats up and the rotation speed of the blades slows down, it is possible that an interturn short circuit has occurred. In this case, you will either have to purchase a new fan or replace the burnt-out stator winding. This service can be provided at a specialized service center.

    Cleaning the heat exchanger

    It is produced with a solution of hydrochloric acid, purchased in a retail chain and intended specifically for this purpose. Cleaning is carried out for the main heat exchangers of wall-mounted gas boilers and heat exchangers for hot water preparation. The cross-section of the channels of such heat exchangers is small, which is why they are susceptible to contamination by salt deposits.

    As a rule, the water jacket of floor-standing gas boilers is not cleaned. To perform cleaning, the heat exchanger must be removed. To do this, remove the boiler casing, unscrew the supply pipes to the heat exchanger, after draining the water from the boiler.

    We remove the heat exchanger from the boiler. Wear rubber gloves and use a plastic container to collect the spent acid. The method is not complicated

    Carefully pour the acid solution into the heat exchanger until it is completely filled. If the heat exchanger is clogged with scale, active foam will be released.

    Leave the heat exchanger for 10–15 minutes.

    We drain the spent acid into a container and refill the heat exchanger with a new portion. We wait the same ten minutes. Drain the solution and rinse the heat exchanger with running water. We put a piece of hose on the nearest water tap and spill water on the heat exchanger. Let's fill the heat exchanger again with an acid solution. If there is no active release of foam, and when the heat exchanger is spilled with water, no significant resistance to flow is visible, it means that the heat exchanger has been washed and can be reinstalled in the reverse order.