Among the variety of heating boilers presented on the Russian market, solid fuel units of domestic production are always popular and have good reviews. Many of them are not inferior in quality to imported analogues, although they have a more affordable price.
The Sibenergotherm plant is one of the manufacturers of heating equipment, represented by a wide range. A high level of production automation ensures precise execution of technological operations and control over compliance with quality standards.
Boiler models
Solid fuel boilers from the Prometheus model range have different operating principles and a power range from 12 to 800 kW. They can be used for heating private houses and industrial facilities. These include the following models:
- Solid fuel boilers with varying power from 12 to 60 kW, designed for 8-12 hours of combustion, have a spacious loading chamber. They are made of heat-resistant steel 4 mm thick. Efficiency from 78 to 84%. Coal of various grades (except anthracite) is used as the main fuel; firewood is used as an additional fuel. It is possible to install heating elements for additional heating of the coolant. The main technical characteristics are presented in the table.
- Automatic long-burning boilers on brown coal Prometheus Automatic with a power from 40 to 800 kW cope with heating rooms from 150 to 8000 m2. Efficiency is up to 85%. Thanks to the large fuel bunker, the heat generator can operate on one load for up to 7 days. Thanks to automation, the temperature set by the owner is maintained at the specified level.
- Universal pellet boilers Prometheus Combi with a power of 25 kW can operate on any type of fuel. In addition to the furnace for burning solid fuel, they can install a burner (gas, diesel or pellet) or heating elements. The heated area can be up to 250 m2. When using pellets as the main fuel, efficiency up to 90% and a high level of automation are achieved.
- Gas generator boilers Prometheus Eco with a power of 30 kW operate on wood. They have two chambers, in one of which fuel is burned, releasing pyrolysis gases, and in the second, these gases burn with a large release of heat. The boiler operation can be adjusted automatically. The combustion chamber is made of refractory concrete. Efficiency is up to 93%.
Solid fuel boiler "Prometheus 12M5" 12 kW
Solid fuel boiler "Prometheus 12 M5"
has a rated power of 12 kW, has an efficiency of up to 84% and is capable of heating a room up to 100 sq.m. The fuel used for heating is coal (20-40 mm), grade DO, which is consumed at a rate of 3.2 kg/h. The volume of water in the boiler is 48 l. With overall dimensions 905x436x690 mm. The heating boiler weighs 160 kg.
Boiler advantages:
- possibility of installing a block of heating elements of various capacities. There is no need to purchase an additional electric boiler;
- automatic power control with a direct-acting draft regulator;
- improved design of the upper loading door of the boiler: low temperature on the surface, tight fit of the loading lid, which prevents smoke from entering the room;
- the loading chamber is designed for 8-12 hours of continuous operation of the boiler;
- The grate bars are made of a more durable grade of cast iron SCh20, as a result of which they do not burn out. Thanks to the new improved design, the grate bars do not jam;
- shaken grate, with the possibility of completely discharging burning coal into the ash pan. When there is a power outage, in order to avoid overheating of the boiler, in the third position of the grate shaking lever, the burning coal is completely dumped into the ash pan;
- three “flame” strokes to increase boiler efficiency;
- boilers are equipped with instruments for monitoring temperature and pressure in the heating system;
- modern design and small dimensions, allowing this solid fuel boiler to be placed in residential premises in limited space;
- ease of operation and maintenance.
Design features of PROMETHEUS boilers
Loading chamber design
Fuel is supplied to the loading chamber manually. One load of fuel ensures long burning, from 8 to 12 hours. Slow heating of the upper layers of fuel helps to significantly reduce the moisture in it, which ultimately helps to increase the efficiency of the boiler.
Ignition of fuel
The fuel is ignited manually. The ignition valve located in the upper part of the heat exchanger at this time opens manually until it stops. This reduces aerodynamic drag when removing smoke, which ultimately leads to increased thrust. Pre-heating of the heat exchanger chamber lasts 10-15 minutes, thus the ignition process in the combustion chamber proceeds faster, after which the damper must be closed, and the boiler goes into operating mode, characterized by the optimal rate of fuel combustion.
Grate
The grate is equipped with a manual shaking lever for cleaning the grate passages. This allows you not to interrupt the operation of the PROMETHEUS boiler. The resulting ash, after shaking, enters the ash box, thereby normalizing it by blowing air into the boiler. The grate is made of cast iron and consists of several elements. Therefore, if necessary, you can replace not the entire grille at once, but only its individual parts.
Boiler materials
The boiler heat exchanger is made of alloyed heat-resistant steel (boiler steel) 4 mm thick. The working life of such steel is more than a million hours of continuous operation under the influence of high temperatures. In areas exposed to the highest temperatures, fireclay bricks are located, which can withstand temperatures up to 1800 degrees Celsius. This prevents burnout of the heat exchanger and the top cover of the boiler.
Autonomy
The PROMETHEUS boiler control system is independent of power sources. Using an automatic thermostat, the air damper opens and closes, thanks to which the heating temperature is maintained according to the specified parameters. A supply pipe with a diameter of up to 50 cm allows the use of PROMETHEUS solid fuel boilers in a heating system with natural and forced circulation. Pressure and temperature sensors built into the front panel allow you to monitor important parameters of the heating system.
Video instructions for installation and operation of solid fuel boilers "PROMETHEUS"
Areas of use of solid fuel boilers
PROMETHEUS boilers can be successfully used for any type of infrastructure due to their ease of use, ease of maintenance and energy autonomy. The boilers are suitable for use in both forced circulation and natural heating systems. PROMETHEUS boilers are an economical, efficient and reliable source of heating created for Russian operating conditions.
Choosing a boiler for your home
To decide which model of solid fuel unit is best suited for your home, first of all, you need to choose the type of fuel. It can be hard or brown coal, firewood, pellets. Sometimes it is advisable to use another energy source, such as electricity, as an emergency or additional source.
The use of pellets or brown coal allows for a high level of automation of the boiler operation and reduces the frequency of approaches to it for loading to once every 5-7 days. For use in regions where there is no possibility of connecting to the power grid or where there are frequent power outages, you should choose non-volatile models.
The power of the Prometheus boiler is chosen based on the area of the house and its heat loss. If you make calculations according to all the rules, you need to take into account the heat loss of all surfaces based on their resistance to heat transfer. This indicator can be found in construction reference books.
In this case, it is necessary to take into account the minimum winter temperatures. The boiler power should replenish the heat loss of the house, but should not significantly exceed it. For an approximate calculation, you can use the ratio of 1 kW per 10 m2 of area with a ceiling height of no more than 3 m.
Advice! For economical fuel consumption, it is necessary to ensure high-quality thermal insulation of all surfaces bordering the external space. The main heat losses occur through windows and roofing. The walls and foundation also need to be insulated.
Operating instructions for solid fuel boiler “Prometheus” TM
Installation method and operating instructions for the solid fuel heating boiler "PROMETHEUS"
View and download the Operating Instructions for the solid fuel boiler “Prometheus” TM
1 Installation method
:
1.1 The room in which the boiler is installed must have a window or door to the street, and be equipped with supply and exhaust ventilation. The premises must meet fire safety requirements and be kept clean.
1.2 Installation of the chimney and cutting of the ceiling and roof is carried out taking into account fire safety requirements.
1.3 The heating boiler is installed on a flat, durable, fireproof base without slopes.
1.4 The height of the chimney is selected from the level of the grate to the pipe cut of at least 6 m or more if the pipe cut falls into the wind pressure zone.
1.5 The chimney is made of a steel pipe with a diameter no smaller than the outlet pipe of the boiler chimney, preferably made of stainless steel. Installation is carried out in such a way that there are as few turns as possible. When turning at an angle of more than 45°, cleaning is installed. The horizontal section of the chimney should not exceed 1.5 m. If condensation appears inside the chimney, the chimney must be insulated.
1.6 The expansion tank is installed at the highest point of the heating system (preferably indoors) and must be reliably insulated. An overflow pipeline of at least Ø25 and a supply pipeline of at least Ø20 are mounted along the shortest path from a straight steel pipe with a slope from the expansion tank and are also reliably insulated.
1.7 A thermometer and a safety group (or necessarily a safety valve) are installed on the boiler supply pipe.
1.8 The distance from the front wall of the boiler to the wall is at least 1.5 m.
1.9 It is not recommended to build the boiler into walls, openings and niches.
2 Operation:
2.1. Before igniting the boiler, make sure that there is a sufficient amount of water in the heating system and that the boiler communicates with the atmosphere through the expansion tank, and that the boiler valve is open.
2.2. When the boiler is operating, it is necessary to maintain the coolant temperature from 65° to 90°C.
2.3. Before the start of the heating season, thoroughly clean the boiler and chimney, and during operation at least once a month, and possibly more often if the combustion mode is not maintained correctly.
2.4 Coal is laid in small portions of 3-5 kg in dry form, no more than 5x6 cm in size, stirring periodically, creating a combustion mirror, but it is not recommended to tightly fill burning coals. The fuel is placed on the grate in a layer no more than 7 cm thick.
2.5 Fuel must be stored in a separate, dry room.
3. IT IS PROHIBITED:
3.1. Raise the pressure in the boiler and boiler above 2 kg/cm2.
3.2. Raise the temperature in the boiler above 90°C.
3.3. Ignite the boiler without making sure that:
ü There is sufficient water in the heating system.
ü The boiler communicates with the atmosphere through an expansion tank (if an atmospheric expansion tank is installed).
ü The boiler valve is open.
ü The safety valve is in good condition
3.4 Filling an overheated boiler with water.
3.5. Make changes to the boiler design.
3.6. Use water from the heating system for any needs.
3.7. Install a chimney with a smaller diameter than the boiler chimney outlet.
3.8. Use fuel not intended for combustion in heating boilers (rubber, plastic, etc.).
3.9. If a membrane expansion tank is installed, fire up the boiler without making sure that the safety group is in working order.
3.10. Use fuel with high moisture content.
3.11. Install a membrane expansion tank without a pressure reducing valve for filling the heating system and a safety group.
Download the Operating Instructions for the solid fuel boiler “Prometheus” TM
Installation and operation
The floor on which the solid fuel boiler will be installed must be strong enough and suitable for its weight. If necessary, an additional foundation larger than the boiler is installed. The floor covering under the boiler must be fireproof and level.
The distance from surrounding surfaces should not be less than 70 cm from the rear and side surfaces, not less than 125 cm from the front surface:
- The delivery kit includes a combustion regulator that needs to be installed in place.
- The connection of the boiler to the chimney must be carried out in accordance with the rules of construction supervision. The height of the pipe must correspond to its power.
- Electric heaters are installed taking into account all requirements. The boiler must be grounded.
Advice! Installation of electrical equipment must be carried out by a qualified representative of a licensed organization.
- The heating supply and return lines are connected to the boiler. The pipes must be laid without tension.
- To avoid exceeding the maximum pressure, an automatic air and safety valve is installed.
- Before starting operation, the boiler with piping must be checked for leaks.
Starting and using the boiler
Antifreeze can be used as a coolant, especially if there is a possibility of freezing. The heating solid fuel boiler is filled to the required pressure when cold. At the same time, air is released. Paper and wood are used to light the boiler.
When the fire burns well, the main fuel is loaded. After this, the flame level is adjusted using air supply. To clear the grate from ash, it is moved using a lever. The ash drawer must be cleaned regularly. It is advisable to invite a specialist once a year to inspect the boiler and check its operation.
Among the model range of Prometheus boilers, you can choose a solid fuel unit for heating any home with an autonomous heating system. The quality of the equipment meets the highest requirements, as evidenced by consumer reviews. To choose the appropriate model, you need to decide on the type of fuel and boiler power.